Airmax MAX-100-E-LV: hydronic heat with an ECM air handler
The Airmax MAX-100-E-LV is a low-velocity hydronic air handler. It moves indoor air across a hot-water heating coil, using water supplied by a suitable boiler or water-heating system. Its ECM blower circulates that warmed air through the home’s ducts. This is the MAXAIR 100e LV hydronic model, not the separately listed electric-heating version or a high-velocity model.
We help select the air handler around the home and the equipment it connects to. That means considering the water-side heat source and the air-side distribution together. An air handler can be compact while still needing correctly sized ducts, suitable water flow and room for access. Those practical connections determine how well the installed system works.
Standard installation is included, carried out by our licensed and insured technicians. No hidden fees: the price above includes the equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee. We provide free GTA delivery, our one-year installation labour warranty and free manufacturer warranty registration. Order online with a $100 deposit and pay the remaining balance after installation, or order by phone without a deposit.
MAX-100-E-LV specifications at a glance
The specifications below describe this exact hydronic ECM model. Heating output changes with entering-water temperature, and the air rating is tied to external static pressure. A cooling application also needs the appropriate cooling coil and connected outdoor equipment. The air handler by itself does not establish a complete system efficiency rating.
We use these figures to explain the equipment choice, not to turn one maximum number into a promise for every installation. The water heater or boiler, circulation arrangement, duct resistance and control settings all affect the final operating conditions. The dimensions describe the cabinet in the manufacturer’s stated order; they do not include every connected accessory or the access space needed around it.
| Item | Details |
|---|---|
| Exact model | Airmax MAX-100-E-LV / MAXAIR 100e LV |
| Equipment type | Low-velocity hydronic air handler |
| Motor | 1 hp ECM |
| Rated airflow | 1,580 CFM at 0.5 in. w.g. external static pressure |
| Electrical supply / current | 120 V, single phase, 60 Hz / 11.4 A |
| Water flow rating | 8 GPM |
| Hydronic connections | ¾-inch copper |
| Heating at 120°F entering water | 61,673 BTU/h |
| Heating at 140°F entering water | 87,074 BTU/h |
| Heating at 180°F entering water | 138,519 BTU/h |
| Listed DX cooling application | 4.0 tons; requires matching cooling equipment |
| Cabinet height × depth × width | 30 × 25½ × 18 inches |
| Top supply opening | 15 × 22½ inches |
| Minimum return opening | 16 × 16 inches |
| Manufacturer warranty | Five-year parts; two-year labour allowance |
Why choose the MAX-100-E-LV?
This model brings together hydronic heating, an ECM blower and a compact, multi-position cabinet. It suits projects where the home’s heating plan uses hot water to supply a fan coil rather than generating heat inside a gas furnace. Multiple return arrangements give the duct layout options, while the exact installation orientation follows the manufacturer’s instructions.
The ECM model provides multiple airflow options and supports staged control applications. Those features make the equipment adaptable to the selected system rather than locking every installation into the same fan setting. We explain the control arrangement as part of choosing the equipment, so the daily thermostat operation connects to the way the home is heated.
Its strongest advantage is the combination of a useful hydronic output range and a defined low-velocity airflow capability. Choosing it still starts with the building’s needs. We help compare the required heat, available water conditions and duct arrangement, keeping the product decision grounded in what the installed system needs to deliver.
How hydronic air heating works
Hot water carries energy from the heat source to the air-handler coil. The blower moves indoor air across that coil, and heat passes into the air before it travels through the supply ducts. Water then returns through the hydronic circuit. The water and air have separate paths; the coil is the transfer point between them.
The MAX-100-E-LV does not burn gas inside its cabinet to produce that heat. It also is not the electric-resistance MAXAIR LV E model. Its electrical supply operates the air handler and associated components, while the hydronic source provides the heating energy. This distinction matters when comparing replacement options with a furnace or an electrically heated air handler.
We help explain the whole equipment arrangement before ordering. A boiler, a compatible combination water-heating system and an air handler have different jobs even when they form one heating system. The useful question is how those parts work together for the property, not whether their model names appear similar.
Heating output follows water temperature
A hydronic fan coil does not have one output that applies at every water temperature. Hotter entering water generally allows more heat transfer under the stated rating conditions. The model’s published heating figures range across entering-water temperatures from 120°F to 180°F, so the operating water temperature is central to equipment selection.
For example, the submittal lists 61,673 BTU/h at 120°F entering water, 87,074 BTU/h at 140°F and 138,519 BTU/h at 180°F. Those are different conditions for the same model, not three interchangeable promises. The published water-flow rating is 8 GPM. The complete rating information needs to stay connected to the proposed water-side design.
Selecting the highest printed output while planning to operate at a much lower water temperature would give the wrong picture. The home’s heat requirement and available supply temperature need to meet at a practical operating point.
Understanding the heat source
The heat source must provide water at the temperature and flow the fan coil needs. A compatible boiler or combination water-heating arrangement can serve this role when designed for it. Simply having hot water available somewhere in the building does not establish that the existing equipment is suitable for space heating through this air handler.
In a combined domestic-hot-water and space-heating system, both demands matter. A shower and a heating call can place different requirements on the system. The manufacturer’s design instructions address the source equipment and piping arrangements; this is a system selection question, not an invitation to connect the coil to any convenient hot-water pipe.
We help with product selection and explain the installation requirements. Where an existing heat source is being retained, its actual capability and intended use shape the air-handler choice. A correctly matched air handler belongs within a complete heating plan rather than replacing that plan.
Water flow, piping and circulation
The submittal identifies an 8 GPM flow rating and three-quarter-inch copper connections. Connection diameter is not the same thing as guaranteed flow. The circulation arrangement has to move water through the coil and connected piping against the resistance of that circuit.
Pipe route, fittings and the selected source equipment affect that resistance. The manufacturer’s installation guidance covers the circulation and control components used in a hydronic system. Their selection is part of qualified installation work, not a setting a homeowner needs to calculate from the product page.
Replacing an air handler with a similar-sized cabinet does not prove that the existing water circuit is correct for the new operating requirements. We explain any work beyond a standard installation before you order, so the scope is clear before the equipment arrives.
Sizing for the home rather than the model number
The “100” in the product name should not be treated as a fixed heating output for every installation. The published output changes with water temperature, as shown in the rating table. Likewise, a room count or a floor-area estimate cannot capture every home’s heat loss, envelope, exposure and distribution needs.
The air handler must meet the heating requirement at the water conditions the system can actually provide. Cooling, when included, creates another set of matching requirements. Both functions share the blower and ducts, so choosing equipment around only one headline number can overlook an important part of the installation.
We help select the model and explain how its capabilities relate to the property. The aim is equipment that fits the intended system, not the largest model that fits through the door. Appropriate capacity and a workable distribution arrangement matter together.
Airflow and external static pressure
The MAX-100-E-LV submittal lists 1,580 CFM at 0.5 inches water gauge external static pressure. CFM describes the volume of air moved over time. External static pressure describes resistance outside the air handler, including the connected distribution path.
A fan operating against a different resistance does not necessarily deliver the same airflow. Supply ducts, return ducts, filters, grilles and a cooling coil all participate in the air path. The rated figure is therefore a useful design point, not an assurance of identical airflow through every existing duct system.
A capable fan cannot make an undersized return path disappear, and a replacement cabinet alone cannot correct every distribution issue. The operating setup needs to work with the connected system so the selected heating and cooling arrangements have appropriate airflow.
What the ECM blower adds
This exact model uses a one-horsepower ECM blower motor. ECM refers to electronically commutated motor technology. Its purpose here is to provide the air movement required by the selected operating mode; it is not an electric heating element.
The equipment supports multiple airflow options. Heating, cooling and circulation can have different airflow needs, and the control arrangement determines how those needs are managed. The manufacturer’s setup instructions provide the reference for the appropriate selections.
We help make those differences understandable during product selection. A homeowner normally interacts with a thermostat rather than the motor’s configuration. Our technicians test the controls and show you how to run the installed system. The goal is straightforward daily operation, with technical setup handled as part of the installation.
Cooling capability and the matching coil
The submittal lists a 4.0-ton DX cooling application for the MAX-100-E-LV and directs reduced-capacity applications to the manufacturer. DX means direct-expansion refrigerant cooling. Using that capability requires the suitable cooling coil, refrigerant components and matched outdoor equipment.
The air handler is not a self-contained air conditioner. It does not establish a SEER2 rating or a certified outdoor-unit pairing on its own. A cooling coil is also not interchangeable simply because it can be placed beside the cabinet. Airflow, physical arrangement and the equipment combination need to work together.
We explain the selected cooling configuration when cooling is part of the purchase. The distinction is practical: the hydronic heating coil moves heat from water to air, while a DX cooling coil uses refrigerant to remove heat from air. These are different components with different installation requirements.
Cooling condensate and access
A cooling coil can remove moisture from indoor air as it operates. That moisture needs an appropriate condensate collection and drainage arrangement. The heating coil’s water circuit and the cooling coil’s condensate drain are different systems, even though both involve water near the equipment.
The coil location and orientation influence the drain arrangement. Access is also important because the coil, filter and connected piping need to remain reachable. Finishing a space tightly around equipment can create avoidable difficulties later if the layout leaves no room for the care described in the manual.
We explain the installation scope around the equipment selected for the home. A heating-only arrangement and one that includes cooling need different connections. Keeping that distinction clear helps the product choice match the actual project rather than an assumed package of accessories.
Supply and return connections
The manufacturer lists a top supply opening of 15 by 22½ inches and a minimum return opening of 16 by 16 inches. These are equipment connection details, not a complete duct-sizing plan for the building. The connected duct system still needs to carry the intended airflow to and from the occupied rooms.
A return path is as important as the supply path. Air pushed into rooms has to get back to the air handler through an appropriate route. Restrictions on either side affect the system’s operating conditions and can change the result expected from the fan rating.
We explain how the air handler connects to the selected layout. The available return arrangements and multi-position installation options can help fit the equipment into a project, while the manufacturer’s permitted cutout locations and clearances remain the reference for the actual work.
Cabinet size and installation orientation
The current submittal lists the cabinet as 30 inches high, 25½ inches deep and 18 inches wide. These dimensions are given in that order so the equipment footprint is clear. Connected ducts, piping, a cooling coil and access space can increase the total installation area.
Multi-position placement provides flexibility, but it does not make every position suitable for every accessory arrangement. The intended airflow direction, service access and connected components have to be considered together. A compact cabinet is useful only when the full assembly remains practical to install and use.
We help relate the product to the available mechanical space. The route into that space matters as well as its final dimensions. Our installation explanation covers the equipment arrangement, and any work outside standard installation is discussed before ordering.
Thermostat and staged operation
The submittal identifies two-stage heating, two-stage cooling and combined staged applications. The actual arrangement depends on the selected controls and connected equipment. A supported control application does not mean that every accessory or thermostat is included.
It is useful to separate a thermostat call from the heating source itself. The thermostat requests operation, the controls coordinate the equipment and the water circuit supplies heat to the coil. Cooling adds its own equipment relationships. Good coordination matters more than simply choosing the thermostat with the most visible features.
At handover, our technicians test the controls and show you the everyday settings for the installed system. That leaves the technical configuration connected to the way the homeowner actually uses the equipment.
Electrical supply and equipment identity
The exact-model submittal specifies 120 volts, single phase and 60 hertz, with a listed current of 11.4 amps. Those electrical details describe the hydronic ECM air handler. They should not be confused with the supply requirements of an electric-resistance heating model.
The boiler, water heater, outdoor cooling unit and other system components can have their own electrical requirements. A single product’s nameplate does not describe every circuit in a combined system. Electrical installation follows the equipment instructions and applicable requirements for the selected arrangement.
MAX-100-E-LV, the high-velocity MAXAIR 100e and the separately listed LV E electric-heating models are different choices. The specification table on this page applies to the hydronic low-velocity ECM model named above.
Comfort, sound and room distribution
Comfort depends on more than the temperature leaving the cabinet. The distribution system needs to carry conditioned air to the rooms that need it, and the return path needs to support that movement. Furniture, grille placement and room layout also affect how delivered air is experienced.
Fan speed, duct routing, mounting and connected components influence sound in occupied spaces. A motor type alone does not establish a fixed sound level for every home. The practical goal is a suitable equipment and distribution arrangement, with settings appropriate to the operating mode.
Our product-selection guidance connects these everyday needs with the installation. A replacement decision can then account for the heating source, available space and air distribution together, instead of treating each as an unrelated detail.
Filtration and manufacturer care
A suitable filter protects the air path and helps keep the equipment clean. Filter selection has to account for the airflow arrangement; a more restrictive filter is not automatically a better fit for every system. The installed filter location also needs to remain accessible.
The manufacturer’s instructions describe filter, coil, fan and related care. These are equipment-owner and qualified-service requirements, not a maintenance-plan offer. Power must be disconnected before the cleaning or service work identified in the manual. The appropriate procedure depends on the component involved.
We provide the product documents so the equipment information remains available after installation. Keeping the air-handler instructions with the other system documents makes it easier to distinguish the needs of the fan coil from those of the boiler, water heater or cooling equipment.
Comparing the equipment choices
The comparison below separates equipment roles rather than ranking one technology as the best answer for every home. A hydronic air handler, a gas furnace and an electric-heated air handler produce or transfer heat differently. The right choice follows the available energy source, building needs and installation arrangement.
Keeping the heat source separate from the air-distribution equipment is particularly useful with a hydronic system: the fan coil can deliver heated air, but its output depends on the water supplied to it. That relationship is central to comparing complete systems fairly.
| Item | Details |
|---|---|
| MAX-100-E-LV hydronic air handler | Transfers heat from a suitable hot-water source to ducted air; ECM blower |
| Gas furnace | Produces heat by combustion within furnace equipment; fuel and venting arrangement differ |
| Electric-resistance air handler | Uses electrical heating elements; different model and electrical requirements |
| Cooling coil with outdoor unit | Provides refrigerant cooling when correctly matched; air handler alone is not the complete cooling system |
Replacement planning and the existing system
A replacement project starts with the equipment already serving the home and the intended result. Cabinet size, water connections and duct openings provide useful information, but matching those physical details alone is not enough. The new unit must also fit the required operating conditions.
Changes to the building can alter the heating and distribution discussion. A renovation, different room use or a newly added cooling system can affect what the replacement needs to support. Existing equipment history is helpful context, not a substitute for selecting the appropriate configuration.
We help choose the replacement and explain the installation. Where the existing heat source is retained, the new air handler still needs a compatible water-side arrangement. Where the project changes several components, the selection needs to keep the complete system coordinated.
Installation in Toronto and the GTA
We provide installation in Toronto and the GTA. Standard installation is included, with free GTA delivery. Our licensed and insured technicians install the equipment, and we explain any additional work before you order. Equipment, delivery and standard installation are covered by the price above; a 3% transaction fee applies when paying by credit card.
Ordering is available online, by phone or through the website chat. Our experts help with product selection and explain the installation. After the order, our HVAC expert calls to confirm the details and arrange the installation date, connecting the equipment purchase to the practical work at the property.
Online orders use a $100 deposit, with the balance paid after installation. Ordering by phone does not require the online deposit. Our one-year installation labour warranty accompanies the manufacturer equipment protection.
Airmax warranty and installation coverage
The current Airmax submittal provides five-year parts coverage and a two-year manufacturer labour allowance from the purchase date. A labour allowance is a specified manufacturer contribution for covered component replacement, not a promise that every possible labour cost is unlimited. The linked Airmax warranty policy explains that coverage.
Because we install it, you get the full Airmax manufacturer warranty, and we register it for you free of charge. This applies to our Ontario installations. We also provide our one-year installation labour warranty, covering our installation work alongside the equipment manufacturer’s protection.
The equipment warranty, manufacturer labour allowance and our installation labour warranty have distinct roles. Presenting each clearly helps the installed purchase remain understandable without treating unlike forms of coverage as the same promise.
Frequently asked questions
Yes. It uses a hot-water heating coil supplied by a suitable heat source, with an ECM blower moving air through the ducts.
No. This is the hydronic ECM model. The manufacturer lists electric-heating LV E models separately.
No. That published output is at 180°F entering-water temperature. Output is lower at the lower water temperatures shown in the submittal, which lists an 8 GPM flow rating.
No. The published airflow point is at 0.5 inches water gauge external static pressure. The connected air path and selected settings affect operation.
No. Its listed 4.0-ton DX application needs suitable cooling equipment and a matching coil. It does not establish a complete-system efficiency rating on its own.
Yes. The price above includes equipment, delivery and standard installation. We explain additional work before you order. A 3% transaction fee applies to credit-card payments.
Five years of parts coverage and a two-year manufacturer labour allowance are listed in the current submittal. We also provide our one-year installation labour warranty.
Yes. We register the manufacturer warranty free of charge for our Ontario installations.
Yes. Phone orders can be arranged without a deposit. Online orders take a $100 deposit, with the remaining balance after installation. Our expert calls after ordering to arrange installation.
Product documents and ordering
We help choose the air handler and explain its installation. The manufacturer documents below provide the exact model data, system instructions and warranty information. Any other questions? Call us at (437) 223-9253. We’re always happy to help.
- Exact MAXAIR 100e LV submittal
- Low-velocity installation and maintenance manual
- Airmax warranty policy