Airmax MAX-70-E High Velocity Air Handler

Original price was: $4,199.00.Current price is: $3,499.00.

$

Original price was: $4,199.00.Current price is: $3,499.00.

$
Order Online, Over the Phone, or Via the Chat Box

Order Now, Pay Upon Delivery

a $100 deposit will be applied

 

+5 years parts warranty +1 year labour warranty +Free GTA delivery +Quick install

PRODUCT DESCRIPTION

Airmax MAX-70-E: hydronic heat with an ECM air handler

The Airmax MAX-70-E is a high-velocity hydronic air handler. It moves indoor air across a hot-water heating coil, using water supplied by a suitable boiler or water-heating system. Its ECM blower circulates that warmed air through the home’s ducts. This is the MAXAIR 70e hydronic model, not the separately listed electric-heating version or a low-velocity model.

We help select the air handler around the home and the equipment it connects to. That means considering the water-side heat source and the air-side distribution together. An air handler can be compact while still needing correctly sized ducts, suitable water flow and room for access. Those practical connections determine how well the installed system works.

Standard installation is included, carried out by our licensed and insured technicians. No hidden fees: the price above includes the equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee. We provide free GTA delivery, our one-year installation labour warranty and free manufacturer warranty registration. Order online with a $100 deposit and pay the remaining balance after installation, or order by phone without a deposit.

MAX-70-E specifications at a glance

The specifications below describe this exact hydronic ECM model. Heating output changes with entering-water temperature, and the published airflow is a nominal value. A cooling application also needs the appropriate cooling coil and connected outdoor equipment. The air handler by itself does not establish a complete system efficiency rating.

We use these figures to explain the equipment choice, not to turn one maximum number into a promise for every installation. The water heater or boiler, circulation arrangement, duct resistance and control settings all affect the final operating conditions. The dimensions describe the cabinet in the manufacturer’s stated order; they do not include every connected accessory or the access space needed around it.

Item Details
Exact model Airmax MAX-70-E / MAXAIR 70e
Equipment type High-velocity hydronic air handler
Motor ¾ hp ECM
Rated airflow 750 CFM nominal airflow
Electrical supply / current 120 V, single phase, 60 Hz / 9.9 A
Water flow rating 7 GPM
Hydronic connections ½-inch copper
Heating at 130°F entering water 41,000 BTU/h
Heating at 140°F entering water 46,278 BTU/h
Heating at 180°F entering water 77,981 BTU/h
Listed DX cooling application 2 or 2.5 tons; requires matching cooling equipment
Cabinet height × depth × width 36 × 19½ × 18 inches
Round supply connection 8 inches
Outlet range 16 minimum; 20 maximum. Manufacturer specifies the median number for maximum DX cooling capacity.
Minimum return opening 16 × 15 inches
Manufacturer warranty Five-year parts; two-year labour allowance

Why choose the MAX-70-E?

This model brings together hydronic heating, an ECM blower and a compact, multi-position cabinet. It suits projects where the home’s heating plan uses hot water to supply a fan coil rather than generating heat inside a gas furnace. Multiple return arrangements give the duct layout options, while the exact installation orientation follows the manufacturer’s instructions.

The ECM model provides multiple airflow options and supports staged control applications. Those features make the equipment adaptable to the selected system rather than locking every installation into the same fan setting. We explain the control arrangement as part of choosing the equipment, so the daily thermostat operation connects to the way the home is heated.

Its strongest advantage is the combination of a useful hydronic output range and a defined high-velocity airflow capability. Choosing it still starts with the building’s needs. We help compare the required heat, available water conditions and duct arrangement, keeping the product decision grounded in what the installed system needs to deliver.

How hydronic air heating works

Hot water carries energy from the heat source to the air-handler coil. The blower moves indoor air across that coil, and heat passes into the air before it travels through the supply ducts. Water then returns through the hydronic circuit. The water and air have separate paths; the coil is the transfer point between them.

The MAX-70-E does not burn gas inside its cabinet to produce that heat. It also is not the electric-resistance MAXAIR 70e E model. Its electrical supply operates the air handler and associated components, while the hydronic source provides the heating energy. This distinction matters when comparing replacement options with a furnace or an electrically heated air handler.

We help explain the whole equipment arrangement before ordering. A boiler, a compatible combination water-heating system and an air handler have different jobs even when they form one heating system. The useful question is how those parts work together for the property, not whether their model names appear similar.

Heating output follows water temperature

A hydronic fan coil does not have one output that applies at every water temperature. Hotter entering water generally allows more heat transfer under the stated rating conditions. The model’s published heating figures range across entering-water temperatures from 130°F to 180°F, so the operating water temperature is central to equipment selection.

For example, the submittal lists 41,000 BTU/h at 130°F entering water, 46,278 BTU/h at 140°F and 77,981 BTU/h at 180°F. Those are different conditions for the same model, not three interchangeable promises. The published water-flow rating is 7 GPM. The complete rating information needs to stay connected to the proposed water-side design.

Selecting the highest printed output while planning to operate at a much lower water temperature would give the wrong picture. The home’s heat requirement and available supply temperature need to meet at a practical operating point.

Understanding the heat source

The heat source must provide water at the temperature and flow the fan coil needs. A compatible boiler or combination water-heating arrangement can serve this role when designed for it. Simply having hot water available somewhere in the building does not establish that the existing equipment is suitable for space heating through this air handler.

In a combined domestic-hot-water and space-heating system, both demands matter. A shower and a heating call can place different requirements on the system. When domestic hot water also supplies space heating, scald protection and potable-water compatibility need qualified design. The heating rating is not a recommended tap-water temperature. The manufacturer’s design instructions address the source equipment and piping arrangements; this is a system selection question, not an invitation to connect the coil to any convenient hot-water pipe.

We help with product selection and explain the installation requirements. Where an existing heat source is being retained, its actual capability and intended use shape the air-handler choice. A correctly matched air handler belongs within a complete heating plan rather than replacing that plan.

Water flow, piping and circulation

The submittal identifies a 7 GPM flow rating and half-inch copper connections. Connection diameter is not the same thing as guaranteed flow. The circulation arrangement has to move water through the coil and connected piping against the resistance of that circuit.

Pipe route, fittings and the selected source equipment affect that resistance. The manufacturer’s installation guidance covers the circulation and control components used in a hydronic system. Their selection is part of qualified installation work, not a setting a homeowner needs to calculate from the product page.

Replacing an air handler with a similar-sized cabinet does not prove that the existing water circuit is correct for the new operating requirements. We explain any work beyond a standard installation before you order, so the scope is clear before the equipment arrives.

Sizing for the home rather than the model number

The “70” in the product name should not be treated as a fixed heating output for every installation. The published output changes with water temperature, as shown in the rating table. Likewise, a room count or a floor-area estimate cannot capture every home’s heat loss, envelope, exposure and distribution needs.

The air handler must meet the heating requirement at the water conditions the system can actually provide. Cooling, when included, creates another set of matching requirements. Both functions share the blower and ducts, so choosing equipment around only one headline number can overlook an important part of the installation.

We help select the model and explain how its capabilities relate to the property. The aim is equipment that fits the intended system, not the largest model that fits through the door. Appropriate capacity and a workable distribution arrangement matter together.

Airflow and external static pressure

The MAX-70-E submittal lists 750 CFM nominal airflow. CFM describes the volume of air moved over time. External static pressure describes resistance outside the air handler, including the connected distribution path.

A fan operating against a different resistance does not necessarily deliver the same airflow. Supply ducts, return ducts, filters, grilles and a cooling coil all participate in the air path. The nominal figure is therefore useful equipment information, not an assurance of identical airflow through every existing duct system.

A capable fan cannot make an undersized return path disappear, and a replacement cabinet alone cannot correct every distribution issue. The operating setup needs to work with the connected system so the selected heating and cooling arrangements have appropriate airflow.

What the ECM blower adds

This exact model uses a three-quarter-horsepower ECM blower motor. ECM refers to electronically commutated motor technology. Its purpose here is to provide the air movement required by the selected operating mode; it is not an electric heating element.

The equipment supports multiple airflow options. Heating, cooling and circulation can have different airflow needs, and the control arrangement determines how those needs are managed. The manufacturer’s setup instructions provide the reference for the appropriate selections.

We help make those differences understandable during product selection. A homeowner normally interacts with a thermostat rather than the motor’s configuration. Our technicians test the controls and show you how to run the installed system. The goal is straightforward daily operation, with technical setup handled as part of the installation.

Cooling capability and the matching coil

The submittal lists a 2- or 2.5-ton DX cooling application for the MAX-70-E and notes that smaller condensers require a suitable matching arrangement, including the correct metering valve. DX means direct-expansion refrigerant cooling. Using that capability requires the suitable cooling coil, refrigerant components and matched outdoor equipment.

The air handler is not a self-contained air conditioner. It does not establish a SEER2 rating or a certified outdoor-unit pairing on its own. A cooling coil is also not interchangeable simply because it can be placed beside the cabinet. Airflow, physical arrangement and the equipment combination need to work together.

We explain the selected cooling configuration when cooling is part of the purchase. The distinction is practical: the hydronic heating coil moves heat from water to air, while a DX cooling coil uses refrigerant to remove heat from air. These are different components with different installation requirements.

Cooling condensate and access

A cooling coil can remove moisture from indoor air as it operates. That moisture needs an appropriate condensate collection and drainage arrangement. The heating coil’s water circuit and the cooling coil’s condensate drain are different systems, even though both involve water near the equipment.

The coil location and orientation influence the drain arrangement. Access is also important because the coil, filter and connected piping need to remain reachable. Finishing a space tightly around equipment can create avoidable difficulties later if the layout leaves no room for the care described in the manual.

We explain the installation scope around the equipment selected for the home. A heating-only arrangement and one that includes cooling need different connections. Keeping that distinction clear helps the product choice match the actual project rather than an assumed package of accessories.

Supply and return connections

The manufacturer lists a round supply connection of 8 inches and a minimum return opening of 16 by 15 inches. These are equipment connection details, not a complete duct-sizing plan for the building. The connected duct system still needs to carry the intended airflow to and from the occupied rooms.

A return path is as important as the supply path. Air pushed into rooms has to get back to the air handler through an appropriate route. Restrictions on either side affect the system’s operating conditions and can change the result expected from the fan rating.

We explain how the air handler connects to the selected layout. The available return arrangements and multi-position installation options can help fit the equipment into a project, while the manufacturer’s permitted cutout locations and clearances remain the reference for the actual work.

Cabinet size and installation orientation

The current submittal lists the cabinet as 36 inches high, 19½ inches deep and 18 inches wide. These dimensions are given in that order so the equipment footprint is clear. Connected ducts, piping, a cooling coil and access space can increase the total installation area.

Multi-position placement provides flexibility, but it does not make every position suitable for every accessory arrangement. The intended airflow direction, service access and connected components have to be considered together. A compact cabinet is useful only when the full assembly remains practical to install and use.

We help relate the product to the available mechanical space. The route into that space matters as well as its final dimensions. Our installation explanation covers the equipment arrangement, and any work outside standard installation is discussed before ordering.

Thermostat and staged operation

The submittal identifies two-stage heating, two-stage cooling and combined staged applications. The actual arrangement depends on the selected controls and connected equipment. A supported control application does not mean that every accessory or thermostat is included.

It is useful to separate a thermostat call from the heating source itself. The thermostat requests operation, the controls coordinate the equipment and the water circuit supplies heat to the coil. Cooling adds its own equipment relationships. Good coordination matters more than simply choosing the thermostat with the most visible features.

At handover, our technicians test the controls and show you the everyday settings for the installed system. That leaves the technical configuration connected to the way the homeowner actually uses the equipment.

Electrical supply and equipment identity

The exact-model submittal specifies 120 volts, single phase and 60 hertz, with a listed current of 9.9 amps. Those electrical details describe the hydronic ECM air handler. They should not be confused with the supply requirements of an electric-resistance heating model.

The boiler, water heater, outdoor cooling unit and other system components can have their own electrical requirements. A single product’s nameplate does not describe every circuit in a combined system. Electrical installation follows the equipment instructions and applicable requirements for the selected arrangement.

MAX-70-E, the low-velocity MAXAIR 70e LV and the separately listed MAXAIR 70e E are different choices. The specification table on this page applies to the hydronic high-velocity ECM model named above.

Comfort, sound and room distribution

Comfort depends on more than the temperature leaving the cabinet. The distribution system needs to carry conditioned air to the rooms that need it, and the return path needs to support that movement. Furniture, grille placement and room layout also affect how delivered air is experienced.

Fan speed, duct routing, mounting and connected components influence sound in occupied spaces. A motor type alone does not establish a fixed sound level for every home. The practical goal is a suitable equipment and distribution arrangement, with settings appropriate to the operating mode.

Our product-selection guidance connects these everyday needs with the installation. A replacement decision can then account for the heating source, available space and air distribution together, instead of treating each as an unrelated detail.

Filtration and manufacturer care

A suitable filter protects the air path and helps keep the equipment clean. Filter selection has to account for the airflow arrangement; a more restrictive filter is not automatically a better fit for every system. The installed filter location also needs to remain accessible.

The manufacturer’s instructions describe filter, coil, fan and related care. These are equipment-owner and qualified-service requirements, not a maintenance-plan offer. Power must be disconnected before the cleaning or service work identified in the manual. The appropriate procedure depends on the component involved.

We provide the product documents so the equipment information remains available after installation. Keeping the air-handler instructions with the other system documents makes it easier to distinguish the needs of the fan coil from those of the boiler, water heater or cooling equipment.

Comparing the equipment choices

The comparison below separates equipment roles rather than ranking one technology as the best answer for every home. A hydronic air handler, a gas furnace and an electric-heated air handler produce or transfer heat differently. The right choice follows the available energy source, building needs and installation arrangement.

Keeping the heat source separate from the air-distribution equipment is particularly useful with a hydronic system: the fan coil can deliver heated air, but its output depends on the water supplied to it. That relationship is central to comparing complete systems fairly.

Item Details
MAX-70-E hydronic air handler Transfers heat from a suitable hot-water source to ducted air; ECM blower
Gas furnace Produces heat by combustion within furnace equipment; fuel and venting arrangement differ
Electric-resistance air handler Uses electrical heating elements; different model and electrical requirements
Cooling coil with outdoor unit Provides refrigerant cooling when correctly matched; air handler alone is not the complete cooling system

Replacement planning and the existing system

A replacement project starts with the equipment already serving the home and the intended result. Cabinet size, water connections and duct openings provide useful information, but matching those physical details alone is not enough. The new unit must also fit the required operating conditions.

Changes to the building can alter the heating and distribution discussion. A renovation, different room use or a newly added cooling system can affect what the replacement needs to support. Existing equipment history is helpful context, not a substitute for selecting the appropriate configuration.

We help choose the replacement and explain the installation. Where the existing heat source is retained, the new air handler still needs a compatible water-side arrangement. Where the project changes several components, the selection needs to keep the complete system coordinated.

Installation in Toronto and the GTA

We provide installation in Toronto and the GTA. Standard installation is included, with free GTA delivery. Our licensed and insured technicians install the equipment, and we explain any additional work before you order. Equipment, delivery and standard installation are covered by the price above; a 3% transaction fee applies when paying by credit card.

Ordering is available online, by phone or through the website chat. Our experts help with product selection and explain the installation. After the order, our HVAC expert calls to confirm the details and arrange the installation date, connecting the equipment purchase to the practical work at the property.

Online orders use a $100 deposit, with the balance paid after installation. Ordering by phone does not require the online deposit. Our one-year installation labour warranty accompanies the manufacturer equipment protection.

Airmax warranty and installation coverage

The current Airmax submittal provides five-year parts coverage and a two-year manufacturer labour allowance from the purchase date. A labour allowance is a specified manufacturer contribution for covered component replacement, not a promise that every possible labour cost is unlimited. The linked Airmax warranty policy explains that coverage.

Because we install it, you get the full Airmax manufacturer warranty, and we register it for you free of charge. This applies to our Ontario installations. We also provide our one-year installation labour warranty, covering our installation work alongside the equipment manufacturer’s protection.

The equipment warranty, manufacturer labour allowance and our installation labour warranty have distinct roles. Presenting each clearly helps the installed purchase remain understandable without treating unlike forms of coverage as the same promise.

Mini-duct outlets and room planning

The MAX-70-E belongs to the high-velocity single-zone range. Its small-duct distribution arrangement is different from a conventional low-velocity supply layout. The exact submittal lists a minimum of 16 outlets and a maximum of 20. These are system-design limits, not a recommendation to place the same number of outlets in every room.

Outlet placement and the allocation of airflow need to follow the room requirements and the manufacturer’s design method. The submittal advises using the median outlet count when aiming for maximum DX cooling capacity. That design condition matters alongside the selected cooling equipment. Simply adding more branches is not a reliable way to increase cooling capacity.

We help relate the equipment selection to the project. Our technicians determine the distribution arrangement, permitted branch routing and appropriate diffuser locations. The result should suit the building, rather than being based only on how many outlets can fit into an existing bulkhead.

Frequently asked questions

Yes. It uses a hot-water heating coil supplied by a suitable heat source, with an ECM blower moving air through the ducts.

No. This is the hydronic ECM model. The manufacturer lists electric-resistance air handlers separately.

No. That published output is at 180°F entering-water temperature. Output is lower at the lower water temperatures shown in the submittal, which lists a 7 GPM flow rating.

No. The submittal lists nominal airflow, and actual delivery depends on the system arrangement. The connected air path and selected settings affect operation.

No. Its listed 2- or 2.5-ton DX application needs suitable cooling equipment and a matching coil. It does not establish a complete-system efficiency rating on its own.

Yes. The price above includes equipment, delivery and standard installation. We explain additional work before you order. A 3% transaction fee applies to credit-card payments.

Five years of parts coverage and a two-year manufacturer labour allowance are listed in the current submittal. We also provide our one-year installation labour warranty.

Yes. We register the manufacturer warranty free of charge for our Ontario installations.

Yes. Phone orders can be arranged without a deposit. Online orders take a $100 deposit, with the remaining balance after installation. Our expert calls after ordering to arrange installation.

Product documents and ordering

We help choose the air handler and explain its installation. The manufacturer documents below provide the exact model data, system instructions and warranty information. Any other questions? Call us at (437) 223-9253. We’re always happy to help.


PRODUCT SPECIFICATION

BrandAirmax
ModelMAX-70-E
SeriesAirmax – MAXAIR
Product TypeAir Handler
Installation IncludedYes
Warranty on parts5 Years
Labour Warranty on our Installation1 Year

Get More Information

Installations available throughout Ontario

By submitting this form, you consent to the collection and use of your personal information to process your request, support your experience throughout this website, and for the purposes described in our privacy policy

More About HVAC Market

How can I order an appliance on HVAC Market?
  1. Order Online: You can easily place an order for your desired appliance through our website’s checkout page. Simply browse our selection of HVAC products, add the appliance you want to your cart, and complete your purchase online.
  2. Order by Phone: If you prefer to order over the phone, give us a call at (437) 223-9253. Our experts will submit your order, while also offering professional consultation on choosing the right appliance and explaining the installation process.
  3. Order via Website Chat: You can also contact us through our website’s chat box. Our team is available to provide consultation and place your order, guiding you through the appliance selection and installation steps.
How does HVAC Market's online shop work?
  1. Submit Your Order: You can easily place an order for your HVAC appliance directly through our website. Whether browsing product pages, using our 24/7 chat box, or calling us at (437) 223-9253, we make the ordering process simple and accessible. Our online platform allows you to shop anytime, compare product features, and find the best match for your needs.
  2. Order Confirmation & Consultation: Once your order is submitted, one of our HVAC experts will Call you to confirm your order and schedule the installation at a time that works best for you. If you have any questions or need guidance on your purchase, our team will provide professional consultation to ensure you’ve made the right choice for your home.
  3. Payment & Delivery: You'll only pay for the appliance upon delivery. We offer a convenient and secure payment process, giving you peace of mind. After your appliance is delivered, our team will proceed with the installation as per the confirmed schedule.
What types of HVAC products and brands do you offer?

At HVAC Market, we offer a wide range of HVAC products to meet your heating, cooling, and air quality needs. Our lineup includes Air Conditioners, Furnaces, Heat Pumps, Water Heaters, and indoor air quality solutions. We’re proud to carry top brands like Keeprite, Lennox, Goodman for Air Conditioners and Furnaces, as well as Lennox and Gree, Kinghome, Kepler and midea for Heat Pumps. For Water Heaters, we offer Navien, Rinnai, Bradford White, and Johnwood. For Boilers and Combi-boilers we offer Rinnai, Navien, and Viessmann. For air quality, we carry Honeywell and AprilAire products, ensuring you have access to the best in the market.

Where can I see my purchase receipt?

After completing your purchase with HVAC Market, you will automatically receive an email with your purchase receipt, providing a detailed summary of your transaction. This email will include important information such as the product details, order number, purchase date, and any relevant warranty information.

For added convenience, we recommend creating an account on our website. With an account, you can easily track your current and past orders in one place. Your order history will be saved under your profile, allowing you to view and download receipts whenever needed. Having an account also makes future purchases faster, as your shipping and billing information can be securely stored for easy access.

Do you offer any warranties or guarantees on your products and services?

Yes, all products installed by HVAC Market come with a one-year unconditional warranty. This means that if any issues arise with the system or installation, we will fix them at no additional cost to you. Additionally, many of the HVAC products we sell come with manufacturer warranties, which can offer long-term protection.

What installation, maintenance, and repair services do you offer?

We provide complete installation services for all of our HVAC products to ensure your system is set up for optimal performance. In addition, we offer maintenance and repair services to keep your system running smoothly year-round. Our team of licensed and insured technicians is available 24/7 to assist with any issues. All installations come with a one-year warranty, so if anything goes wrong, we’ll fix it for free. To schedule maintenance or repair, you can reach our call center at (437) 223-9253.

Do you provide emergency HVAC services?

Yes, we provide emergency HVAC services to ensure your comfort no matter the situation. If your system breaks down unexpectedly, you can contact our call center at (437) 223-9253, and we’ll dispatch a licensed technician to resolve the issue as quickly as possible.

How can I determine the best HVAC system for my home, and what factors affect pricing?

Finding the right system for your home is easy with our selection tool, which helps recommend products based on your home size, climate, and energy efficiency goals. Detailed product pages also allow you to compare specs and pricing, making it simple to find the best fit. As for pricing, it’s calculated by considering the cost of the appliance, installation materials, and standard installation fees. We offer free transportation within our service area, and every installation comes with a one-year unconditional warranty to ensure your satisfaction.

What makes HVAC Market different from other HVAC service providers?

At HVAC Market, we pride ourselves on offering a comprehensive selection of high-quality products, expert installation, and reliable maintenance services. Our transparent pricing, free transportation, and one-year warranty on installations set us apart. Plus, our commitment to customer satisfaction means we go the extra mile to ensure you get the right product for your home, backed by professional support every step of the way.