The Rinnai IP199S I-Series Plus is an indoor, wall-mounted condensing boiler for a home with hot-water space heating. Its burner operates from 15,000 to 199,000 BTU/h, and its published heating capacity is 181 MBH. The 95% AFUE rating describes its standardized seasonal heating efficiency. It is a heating-only boiler, not a combi, so a separate indirect tank is needed when the boiler will also provide domestic hot water.
We explain the equipment and installation together, so the decision starts with the heating system in your home. Installation is included. No hidden fees: the price above includes the equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee. We provide free GTA delivery, and if your home needs anything beyond a standard installation, we go over it with you before you order.
We offer two payment options: order online with a $100 deposit and pay the remaining balance after installation, or order by phone without a deposit. Our experts explain the installation and help you choose the appliance. After an order, we call to confirm it and schedule installation.
An indoor Rinnai boiler for a hydronic heating system
The I-Series Plus uses heated water to carry energy to the home’s heating emitters. A suitable system can use radiators, hydronic baseboards or another properly designed hot-water distribution arrangement. The boiler heats the circulating water; the emitters transfer that energy into the rooms. This is a different heating arrangement from a furnace blowing warm air through ducts.
The heating distribution establishes which type of equipment can serve the existing rooms. A house with a familiar radiator system is not choosing a furnace simply because both appliances burn gas. The existing distribution system, required water temperatures and building heat loss shape the boiler decision. A heating-only boiler also does not replace a domestic water heater by connecting drinking-water taps directly to its heating circuit.
The IP199S is intended for indoor installation and uses natural gas, with propane operation available through field conversion. Fuel selection is part of the appliance setup and professional installation. Space heating and domestic water have separate connection requirements. Existing water-heating equipment or a properly connected indirect tank determines how the household supply is heated.
Exact IP199S specifications
The table below identifies the IP199S’s own ratings. Gas input is fuel supplied to the burner; heating capacity is heat delivered for heating. Those figures describe different quantities. MBH means thousands of BTU per hour. The heating-capacity figure describes a different quantity from burner input, and room delivery also follows emitter performance. The electrical supply is required for operation, including the appliance controls.
| Specification | Value |
|---|---|
| Model | IP199S |
| Gas input | 15,000–199,000 BTU/h |
| Heating capacity | 181 MBH |
| AFUE | 95% |
| CH turndown | 13.3:1 |
| Central heating setpoint | 86–180°F (30–82°C) |
| Electrical supply | AC 120 V, 60 Hz |
| Unit weight | 112.4 lb |
| Cabinet width × height × depth | 19.45 × 34.88 × 15.48 inches |
| Published sound level | 42 dB(A) |
| Boiler pump | External pump required |
Why choose the I-Series Plus IP199S?
This model combines a modulating burner, a stainless-steel water-tube condensing heat exchanger and outdoor reset control with an outdoor temperature sensor. The wall-mounted arrangement offers a different equipment layout from a floor-standing boiler. Its 13.3:1 published central-heating turndown describes the relationship between maximum and minimum burner input for this model.
These features respond to different operating conditions within a hydronic heating system. Modulation gives the burner a range of firing rates. Outdoor reset changes the heating-water target with outdoor conditions. Condensing operation recovers additional heat when operating conditions support it. Together, these are useful design features for a heating system whose demand changes through the season.
Our experts help you choose equipment for the home’s heating arrangement. We explain the installation process with the purchase. A smaller maximum input is useful when it fits the building; a larger one is useful when its extra capacity is needed. The capacity range must suit the actual load. Choosing a larger maximum does not change the heat required by the building or guarantee lower fuel spending.
Sizing starts with building heat loss
A heat loss calculation estimates how much heating a building needs during the design winter conditions. Insulation, air leakage, windows, exposed surfaces and the indoor temperature all affect that result. Two houses with the same floor area can require different heating capacities. A boiler’s model number or the rating on old equipment cannot answer all those questions.
The IP199S has a maximum gas input of 199,000 BTU/h and a published heating capacity of 181 MBH. These are useful equipment-selection values, but they are not a square-foot coverage guarantee. The system also needs enough emitter capacity to deliver the required heat into each room at its operating water temperature.
We explain the selected boiler in the context of the heating arrangement you are buying. We also go over any work beyond a standard installation before you order. That gives you a clear purchase and installation explanation without asking you to size the appliance from a generic online floor-area rule.
Modulation and the importance of the minimum firing rate
The maximum rating matters during high demand, while the minimum rating matters when the load is small. This model’s input range starts at 15,000 BTU/h. During milder weather, or when only a small zone needs heat, the building’s current requirement can be much lower than its winter peak. The boiler and controls have to work with both conditions.
A 13.3:1 turndown ratio does not mean the appliance runs continuously at any heat demand. Below its available firing range, heating operation still involves cycles. Zone arrangement, circulating water and control settings influence how the system responds. Oversizing the boiler adds maximum capacity without necessarily improving operation during a small call for heat.
Maximum input relates to larger heating calls, while minimum input matters during mild weather and smaller zone calls. The useful comparison is not just which model has the largest burner. It is which capacity range works with the heating requirement and the way rooms or zones call for heat in your home.
Condensing efficiency and return water temperature
Condensing boilers recover heat from the combustion process, including heat associated with water vapour in the exhaust. Cooler return water supports that recovery. Return water temperature is therefore an important link between a boiler’s design and the way the connected heating system operates through the season.
The 95% AFUE value is a standardized seasonal rating. Operating conditions change through the heating season, so an individual operating hour and the household fuel bill measure different things from the standardized rating. Weather, thermostat use, the old heating system and the building itself all influence the eventual fuel consumption.
Heating-water temperature affects the opportunity to recover additional heat from the exhaust. A radiator system needing hotter water on the coldest days has different operating conditions from a lower-temperature system. Outdoor reset can lower the target as outdoor conditions become milder. This helps explain why emitter sizing, control settings and water temperature belong in the same equipment conversation.
Radiators, baseboards and water-temperature requirements
Heat emitters deliver a different amount of heat at different water temperatures. A radiator or baseboard that is adequate with hotter water is not automatically adequate at a much lower temperature. Changing the boiler does not change the heat loss of a room or the size of the existing emitter.
The published central-heating setpoint range is 86–180°F, or 30–82°C. That range describes the appliance’s available temperature settings. It is not a recommendation to select the highest setting for every home, or to send high-temperature water into an application designed for lower temperatures. The heating system determines the appropriate operating approach.
The boiler supplies the hydronic circuit, while the emitters transfer that heat into the rooms. Existing radiators, separate heating zones and any lower-temperature circuits matter when describing the installation. A useful replacement maintains the connection between the boiler’s operating range and the heat distribution the rooms actually need, instead of treating a new boiler as an isolated box.
Closed-loop circulation and the external boiler pump
The heating side is a closed-loop hydronic system. Water moves from the boiler to the heating distribution and returns to be heated again. Adequate flow is necessary to transfer the heat produced by the burner. Pipework, valves, pumps and zone arrangements influence that flow and the pressure loss the circulating system must overcome.
An external boiler pump is required for these Solo models. The pump is selected for the heating circuit and its required flow, not simply for the boiler’s maximum input. Pump selection and the system piping arrangement need to work with the appliance’s flow requirements and the connected heating circuits. The manufacturer requires hydraulic separation with primary-secondary piping when connecting the water supply; the connected zones also need an appropriate piping and control arrangement.
We explain what the equipment is and go over any work beyond a standard installation before you order. The appliance, field circulation components and zone controls have separate roles. Pump selection follows the connected circuits and their flow requirements. The manufacturer’s optional primary-secondary heating kit is a system-design option, not a reason to overlook the existing pipework.
Outdoor reset and everyday heating control
Outdoor reset control uses an outdoor temperature sensor to adjust the central-heating water target as outdoor conditions change. The boiler does not need the same target water temperature on a mild day as it does during more demanding weather. The sensor is listed among this model family’s included components.
The user controls and outdoor reset have different jobs. A heating-water temperature target is not the same as the room thermostat’s desired air temperature. When outdoor reset is active, the central-heating target follows the selected reset curve and its associated settings. Increasing a displayed number is not a substitute for a properly configured control arrangement.
We test the controls and show you how to run your new system. That operating explanation helps connect the room heating controls with the boiler display. The manual also describes a boost mode that can override the outdoor-reset target. Settings that affect system operation belong with the professional setup and the manual’s instructions, rather than trial-and-error adjustments to an unfamiliar heating system.
Domestic hot water needs an indirect tank
The IP199S is not a combi boiler. It has no built-in domestic hot-water plate heat exchanger for supplying taps directly. A separate indirect tank is the appropriate type of arrangement when this heating-only boiler also provides domestic hot water. Boiler water heats the tank through a heat exchanger while the domestic supply remains a different water circuit.
The indirect tank, its capacity, controls and recovery arrangement are part of that system selection. A heating-only boiler’s heating rating is not a tankless tap-flow rating. Nor does adding an indirect tank mean all available heat is delivered to room heating and domestic recovery at full output simultaneously. Control priorities and the chosen system design govern the operation.
We explain whether the purchase is for space heating alone or for a boiler working with an indirect tank. A combi comparison is useful when a buyer wants both functions in one appliance. It is a different equipment choice with its own domestic flow and temperature-rise ratings, not an extra built-in feature of this Solo model.
Gas, electricity and winter freeze protection
The appliance needs the correct gas supply and AC 120 V, 60 Hz electrical power. Electronic ignition and controls require electricity, and the circulating system also relies on powered components. A gas-fired boiler is therefore not an electricity-independent heating solution during an outage.
Rinnai’s user manual explains that internal freeze protection needs both gas and electrical power. That protection does not necessarily prevent the connected system piping from freezing. A boiler installed indoors is still part of a building with pipe runs, cold spaces and weather exposure that require an appropriate winter protection plan.
Internal freeze protection concerns the appliance under its required operating conditions. Connected pipes and the building also need protection during freezing weather. An unoccupied house or an extended interruption in heat calls for appropriate professional preparation. The manual’s draining and protection instructions are important; simply turning off utilities in freezing weather is not a substitute for protecting the appliance and the water-filled system.
Canadian venting and combustion air
A condensing boiler needs a suitable combustion-air and exhaust arrangement. Vent material, pipe size, equivalent length, fittings, termination and clearances work together as an approved system. A new wall-mounted location is not suitable merely because there is enough wall space for the cabinet.
Rinnai’s Canadian instructions require ULC S636-listed thermoplastic venting. The permitted materials, pipe, fittings and terminations need to follow the appliance and vent-system instructions as a complete system, with lengths and clearances appropriate to the selected configuration.
The vent system and its termination need to follow the instructions applicable to this Canadian installation. Rinnai also issued a technical bulletin revising Canadian termination clearances near a window or door that can open. The correct arrangement follows the current instructions for the exact installation. Safe termination location and adequate combustion air remain essential even when replacing an existing gas appliance.
Condensate drainage belongs in the installation plan
Condensing operation produces liquid condensate that must leave the boiler through the intended drain arrangement. That drainage is part of installing the appliance, alongside the heating-water, gas, electricity and vent connections. A boiler location without a suitable drainage route needs attention before it becomes a workable equipment location.
The condensate system must follow the appliance instructions and applicable local requirements, including neutralization where required. The manufacturer lists a condensate neutralizer as an optional accessory. That listing does not mean a neutralizer is built into every boiler or that it can be ignored when the installation requires one.
Our installation explanation covers any additional work before you order, with the drainage route considered alongside the appliance’s other connections. Condensate is an ordinary consequence of a condensing appliance, but the drainage route and protection from freezing are still functional parts of the completed heating system.
Water quality and the heating circuit
Water quality matters because water circulates through the boiler’s heat exchanger and the connected heating system. The appliance’s installation instructions address acceptable water conditions, system materials and approved treatment. A closed heating circuit is different from a fresh domestic-water supply that is continuously drawn through household taps.
Oxygen entering a hydronic system and unsuitable materials or additives can damage equipment. Antifreeze selection is also a professional system-design decision; a product used in another application is not automatically suitable for a boiler. The manufacturer identifies unapproved antifreeze, improper water quality and unsuitable open-loop arrangements among conditions that can affect the equipment.
Closed-loop heating water and the system’s materials need to be compatible with the manufacturer’s requirements. Existing pipe materials, any glycol mixture and the condition of an older circuit are relevant to that discussion. Water quality and fluid selection remain technical operating requirements for the connected heating circuit. The technical requirements belong with the manufacturer’s instructions and the professional work needed for the particular installation.
Wall mounting and access around the boiler
Wall mounting changes the equipment layout, but it does not remove the need for safe access. The boiler needs an appropriate supporting location and room for its connections, venting and future professional attention. The manufacturer lists a mounting bracket with the appliance.
A cabinet that fits into a space is only one part of a suitable location. Gas and water piping must reach the proper connections, the condensate needs a drainage route, and the vent system needs an acceptable path outdoors. Required clearances distinguish between basic installation spacing and space needed for professional access.
The installed layout includes the mounting surface, required access and routes for the connected piping and vent system. A photograph of a compact boiler is useful for understanding the equipment format, but it cannot establish the suitability of every closet or utility area. The completed arrangement needs to work as a heating system, including the connections that extend beyond the front of the appliance.
Comparing a heating boiler with other equipment
The comparison below separates the job of the appliance from its fuel source. A boiler circulates heated water through a hydronic system. A furnace distributes heated air through ducts. A combi boiler combines space heating with domestic hot-water production inside the appliance, with its own limits on domestic output.
The distribution system and domestic-water arrangement determine which of these approaches fits the home. Keeping an existing hydronic distribution system can point toward another boiler, while choosing a combi also introduces domestic flow and incoming-water-temperature considerations. An indirect tank offers another approach to storing and recovering domestic hot water alongside a heating-only boiler.
Different Solo boiler sizes offer different maximum heating inputs. This IP199S model reaches 199,000 BTU/h and its minimum input is 15,000 BTU/h. Choosing among capacity ranges starts with the building load and emitter arrangement, not an assumption that a larger burner is always better. We explain the equipment choices with the installation, keeping the capacity decision connected to the home.
| Equipment | Space heating | Domestic hot water |
|---|---|---|
| Heating-only boiler | Hydronic emitters | Separate indirect tank arrangement |
| Combi boiler | Hydronic emitters | Built-in domestic hot-water production |
| Furnace | Warm air through ducts | Separate water heater |
Replacing an older boiler in Toronto and the GTA
A replacement is an opportunity to understand the existing heating arrangement as well as choose new equipment. The current boiler’s fuel, vent route, electrical connection, heating pipework and domestic-water arrangement all affect the work. The aim is a clear plan for connecting the selected appliance to the home it will serve.
We provide free delivery in the GTA and include standard installation in the price above. Our licensed and insured technicians install the equipment. We also provide free removal and disposal of the old unit. If the home needs anything beyond a standard installation, we go over it with you before you order.
We call after an order to confirm it and schedule installation. Our technicians test the controls and show you how to run the new system. That gives you a practical operating handover, with the room controls and the boiler’s everyday operation explained together.
Manufacturer care guidance for long-term operation
Rinnai recommends an annual inspection by a licensed professional. Work on gas, combustion, venting and internal boiler components requires the appropriate licensed professional, following the appliance’s instructions.
Keeping combustion-air openings and the termination unobstructed matters to operation. So does attending to leaks, unusual operating behaviour and the condition of the connected heating system. The manual gives the relevant safety instructions; the product’s efficiency rating is not a reason to ignore professional care or operate equipment with an unresolved fault.
Rinnai manufacturer warranty for our Ontario installations
When we install it, you get the full Rinnai manufacturer warranty, and we register it for you free of charge.
Residential Rinnai manufacturer coverage is 12 years for the heat exchanger, five years for other parts and components, and one year of reasonable manufacturer labour for this Solo boiler. The manufacturer also publishes a five-year heat-exchanger period for commercial applications. Those are different uses of the equipment, so the residential and commercial figures are not interchangeable.
We provide a one-year installation labour warranty on our work. We also register the manufacturer warranty for you, free of charge. The manufacturer’s equipment coverage and our installation labour warranty describe different responsibilities; registration is not an extension of the boiler’s rated capacity or a substitute for proper installation and care.
Rinnai’s manufacturer warranty statement is included with the linked installation manual, alongside the product’s operating instructions.
Ordering and payment for your GTA boiler installation
We offer online and telephone ordering so you can choose the route that works for you. Online ordering takes a $100 deposit, with the remaining balance after installation. Phone orders can be arranged without a deposit. We explain the equipment and installation and call after the order to schedule the work.
The price above includes the equipment, delivery and standard installation, with no hidden fees. There is a 3% credit-card fee on credit-card payments. We explain any work beyond a standard installation before you order, keeping the purchase connected to the home’s installation requirements.
Any other questions? Call us at (437) 223-9253. We’re always happy to help.
Frequently asked questions about the IP199S
No, it is a heating-only Solo boiler. Domestic hot water requires a separate indirect tank arrangement or other water-heating equipment; there is no built-in combi domestic plate exchanger.
15,000–199,000 BTU/h is the published gas input range. The maximum describes burner input, while the model’s separate heating-capacity rating is 181 MBH.
95% AFUE is the published rating for this exact model. Seasonal fuel use also reflects the building, controls, water temperatures and weather; the rating is not a household savings guarantee.
No, an external boiler pump is required. The heating pipework and circulation arrangement must be designed for the appliance and connected heating circuits.
Yes, propane operation is available with field conversion. The correct fuel setup and gas supply are part of the professional installation.
No, electrical power is required for normal operation. Internal freeze protection also needs gas and electricity and does not necessarily protect all connected system piping.
Yes, standard installation is included. We provide free GTA delivery and explain anything beyond a standard installation before you order.
Yes, you can order by phone without a deposit. Online ordering uses a $100 deposit with the remaining balance after installation.
Yes. When we install it, you get the full Rinnai manufacturer warranty, and we register it for you free of charge. Residential Rinnai coverage is 12 years for the heat exchanger, five years for other parts and one year of reasonable manufacturer labour. Our one-year installation labour warranty covers our work.
The manual recommends an annual inspection by a licensed professional. Care follows the manufacturer instructions and is performed by an appropriate licensed professional.
Furnaces
Garage Heaters
Air Conditioners
Air Handlers
Heat Pumps
Mini- Splits
Tank Water Heaters
Tankless Water Heaters
Combi-Boilers
Boilers
ERV (Energy Recovery Ventilators)
HRV (Heat Recovery Ventilators)
Humidifiers
Filter Cabinets
Air Purifiers

