Lifebreath METRO XTR: compact energy recovery ventilation
The Lifebreath METRO XTR is a compact residential energy recovery ventilator, or ERV. It brings outdoor air into the home and exhausts indoor air through an energy-recovery core. This low-profile model is rated for 140 CFM of net supply airflow at 0.3 inches water gauge external static pressure. Its role is ventilation, distinct from space heating and cooling.
Its low-profile cabinet is designed for condos, apartments and townhomes where mechanical space is limited. Ceiling or wall mounting brackets are supplied, and the hinged door provides access to the internal components. Side connections organize the incoming and outgoing air paths, while separate impellers move the two airstreams. We help you select the appliance for the home and explain the installation, bringing the equipment choice and its duct connections into one conversation.
The goal is a ventilation system that fits the building and is straightforward to use. More airflow is not automatically better, and a compact unit is not automatically suitable for every small home. The required ventilation rate, duct resistance and control arrangement determine whether this model is the right fit. We keep those practical decisions central to product selection.
- Standard installation is included, carried out by our licensed and insured technicians.
- No hidden fees: the price above includes the equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee.
- Free GTA delivery and our one-year installation labour warranty.
- Order online with a $100 deposit and pay the remaining balance after installation, or order by phone without a deposit.
- After you order, our HVAC expert calls to confirm the details and schedule installation.
METRO XTR specifications and rating conditions
The following figures apply to the METRO XTR. An airflow number needs its pressure condition, and a recovery-efficiency number needs its test temperature and flow. Keeping those conditions together makes a comparison meaningful. The cabinet measurements describe the unit, not the complete installation space.
| Specification | METRO XTR |
|---|---|
| Model | Lifebreath METRO XTR |
| Product type | Residential energy recovery ventilator |
| Net supply airflow | 140 CFM at 0.3 in. w.g. / 75 Pa |
| Sensible recovery efficiency, mild test | 77% SRE at 64 CFM and 0°C / 32°F |
| Sensible recovery efficiency, cold test | 63% SRE at 70 CFM and −25°C / −13°F |
| Total recovery efficiency, summer test | 53% TRE at 64 CFM and 35°C / 95°F |
| Electrical supply / rated current | 120 V, 60 Hz / 1.2 A |
| Published power point | 77 W at 64 CFM |
| Width × depth × height | 26 × 22 × 10 inches |
| Unit / shipping weight | 42 / 44 lb |
| Duct connections | Four 6-inch round collars |
| Filters | Washable MERV 6 supply and exhaust filters |
| Defrost | Temperature-activated fan defrost |
| Drain | Not required |
| Manufacturer residential warranty | Five-year ERV core; five-year replacement parts |
Why choose the METRO XTR?
This model combines a small physical footprint with a defined residential ventilation capacity. Its ceiling-mount arrangement can be useful where a ventilator needs to fit a suitable bulkhead or ceiling space. The cross-flow core transfers heat and water vapour, and the separate supply and exhaust air paths provide a controlled exchange with outdoors.
The removable core and washable filters make the equipment accessible for the care described in the METRO manual. Multiple fan speeds give the system different operating levels, while the final control selection determines the everyday choices available on the wall. The control arrangement is part of choosing the installed system.
These features make the METRO XTR worth considering for a properly matched residential ventilation application. The strongest reason to select it is the fit between ventilation demand, available space and a workable duct route. We help compare those needs with the product rather than treating a higher airflow rating as a universal upgrade.
What an ERV adds to a home
Heating and cooling equipment can circulate indoor air without bringing in a planned amount of outdoor air. An ERV has a different job: it connects the home to outdoors through a controlled supply and exhaust arrangement. Heat recovery reduces the temperature difference the heating system has to address compared with introducing the same outdoor air without recovery.
That does not turn ventilation into free heating. The ventilator uses electricity, the incoming air still has to be brought to a comfortable indoor condition, and the home still needs its heating equipment. An ERV is one component in a complete indoor environment, alongside source control, filtration and appropriate humidity management.
We help explain where the ventilation product fits in the existing system. It is useful to separate the question of how a room is heated from the question of how outdoor air reaches the home. A replacement furnace and a new ventilator solve different needs, even when the two systems share part of the air-distribution arrangement.
Sizing by required airflow, not a square-foot promise
An ERV is selected around a required ventilation rate and the resistance of the installed ducts. Floor area is only one part of the building context. Occupancy, room layout, how the home was constructed and the intended operating pattern all matter. Floor area alone does not establish the ventilation rate this home needs.
The rated 140 CFM at 0.3 inches water gauge is an equipment performance point, not a guarantee of the flow delivered through any duct layout. A short, direct route and a restrictive route present different loads to the fans. The ventilation design needs to account for that distinction before selecting the operating settings.
We help with model selection and explain the installation requirements for the property. For a replacement, the nameplate of the old ventilator is useful context, but it is not the only selection criterion. Changes to the home and the condition or arrangement of existing connections can affect which equipment is suitable now.
Understanding CFM and external static pressure
CFM means cubic feet per minute, a measure of air volume moving over time. External static pressure describes the resistance presented by the connected air path. These are linked: the fan has to move air through ducts, fittings, grilles and outdoor connections, so an airflow rating cannot be separated from the system resistance.
Lifebreath publishes a performance table for this model rather than a single unlimited airflow promise. That is the useful way to compare ventilators. The operating point has to fit the required flow, and both the supply and exhaust sides need attention. Quoting a gross fan flow as if it were delivered fresh air would blur an important distinction.
We keep the comparison focused on the published net supply rating and its pressure condition. The result is a clearer buying decision: select capacity for the ventilation design, then use a suitable operating setup. A larger-looking number measured under a different condition is not automatically the better match for the home.
Energy recovery: sensible and total ratings
The core transfers heat between the outgoing and incoming airstreams. In heating weather, that process tempers the incoming outdoor air using heat that would otherwise leave with the exhaust. The air paths have separate functions; the purpose is heat exchange, not simply blowing exhaust air back into the living space during normal ventilation.
Sensible recovery efficiency, abbreviated SRE, and total recovery efficiency, abbreviated TRE, measure different aspects of performance. The published 77% SRE point is at 64 CFM and 0°C. The 53% TRE point is at 64 CFM and 35°C, describing a summer test that includes the moisture-related energy component. These percentages do not represent the same test.
A recovery rating is not the percentage reduction in a household energy bill. Actual energy use includes the building’s heat loss, ventilation schedule, weather and other equipment. We explain how recovery fits the system choice while keeping laboratory ratings distinct from household operating costs. The practical benefit is recovering useful heat during planned air exchange.
Cold-weather operation and fan defrost
Cold weather creates a particular challenge for heat recovery equipment: moisture from indoor air can form frost as the core operates against very cold outdoor conditions. The METRO XTR uses temperature-activated fan defrost to manage that process. Defrost is an operating function, not evidence that the ventilator has become a space heater.
During fan defrost, the supply fan stops while the exhaust fan continues to run. Warm exhaust air helps defrost the core, and balanced ventilation resumes when the supply fan restarts. That temporary exhaust-only operation is different from continuous balanced airflow. The selected installation must accommodate the actual operating sequence.
Our handover covers everyday operation so the control choices have a practical meaning. The manufacturer’s instructions remain the reference for how the unit operates in winter. A functioning defrost system does not remove the need to keep outdoor connections clear or to follow the permitted installation arrangement. Those are separate parts of a reliable ventilation installation.
Cabinet dimensions, ceiling mounting and access
The cabinet measures 26 × 22 × 10 inches in width, depth and height order. Its unit weight is 42 lb; the 44 lb shipping figure includes packaging. The side-mounted collars use six-inch round duct connections. The low-profile cabinet is 10 inches high; access and duct connections need additional planning space. Those measurements help establish the equipment footprint before considering the connected ducts.
Usable space is larger than the cabinet alone. The hinged access door needs room to open, and the core needs a path for removal. Lifebreath recommends 22 inches of front clearance for servicing. Crowding the front with stored items or permanent equipment makes future access harder even when the unit physically fits.
We explain the installation arrangement and any work beyond a standard installation before you order. A compact cabinet is an advantage only when the complete layout remains practical. Support, duct bends and service access all share the same space, so the replacement cannot be judged by width and height alone.
Duct connections and balanced air exchange
The four connections have distinct jobs: outdoor supply into the unit, fresh air toward the home, indoor exhaust into the unit and stale air toward outdoors. Correct routing matters. The system is designed around paired supply and exhaust flows, not an arbitrary mix of connections that happen to fit the collars.
Balancing is part of the ventilation installation requirements described by Lifebreath. A measured flow on one side does not establish the flow on the other. The unit includes balancing provisions, but the connected system determines how they are used. The aim is the intended supply and exhaust relationship for the home.
We help select the equipment and explain its installation as a complete system. Reusing existing ducts is a layout question, not an automatic benefit of choosing the same collar diameter. Duct condition, route and connection purpose still matter. The manufacturer installation manual provides the technical reference for the permitted arrangements and setup.
Working with a forced-air system or dedicated ducts
ERV installations can distribute air through a dedicated arrangement or through a suitable connection with a forced-air system. Those choices affect where fresh air enters, where indoor air is collected and how the equipment operates together. The correct layout is specific to the building and the manufacturer’s installation instructions.
A furnace blower circulating air is not the same as an ERV exchanging air with outdoors. In a connected arrangement, the control relationship between the systems is important. The METRO manual describes installation and control relationships for connected forced-air equipment. The selected system must follow the instructions for this exact model, not a different METRO variant.
The selected arrangement determines which control modes are available. A home with an existing central system and a home using other heating equipment can need different ventilation routing. The product decision is therefore about both the appliance and the distribution approach that makes sense for that home.
Controls, timers and everyday operation
The available operating modes depend on the compatible control selected for the installation. A basic wall control and a more capable digital control can offer different choices. Optional timers can provide a temporary ventilation boost in suitable arrangements. Their availability is not a claim that every accessory is included with this product.
It helps to separate three ideas: fan speed, ventilation schedule and humidity-responsive control. A speed changes airflow; a schedule changes when the system runs; a humidity setting responds to measured conditions when that function is provided. Treating those as one setting can make an otherwise straightforward system feel confusing.
Our technicians test the controls and show you how to run the installed system. We also explain the selected equipment during ordering, so the daily interface is part of the decision. The intended result is a clear routine for using ventilation, with the manufacturer manual available when a less frequently used setting needs explanation.
Humidity transfer and the difference from an HRV
An ERV transfers both heat and water vapour through its recovery core. An HRV primarily recovers sensible heat, without the same moisture-transfer function. In winter an ERV can retain some moisture that would otherwise leave in exhaust air; in humid summer conditions it can reduce the moisture load of incoming ventilation air relative to ventilation without that exchange.
Outdoor air can help lower indoor humidity when it is drier than the air being exhausted. During humid weather, ventilation is not a substitute for dedicated dehumidification or the home’s cooling system. A humidity-responsive control also cannot change the moisture content of the outdoor air itself.
We help keep the equipment roles clear when discussing selection. A persistent moisture problem needs its cause understood; a ventilator is not a promise to cure every window-condensation or dampness issue. The choice between ERV and HRV follows the building’s ventilation and humidity needs, along with the performance data of the exact alternatives.
Filters, dry core care and drain provisions
The METRO XTR has washable MERV 6 filters in its supply and exhaust paths. These filters are part of protecting and maintaining the ventilation system; they are not a HEPA purification claim. Lifebreath lists a MERV 13 upgrade, which is a separate option to assess with the intended airflow arrangement.
The current model specification identifies this unit as not requiring a drain. That differs from a drain-required HRV. The supplied installation instructions remain the reference for any application-specific water-management requirements. The access door and filters must remain accessible after installation.
The METRO manual specifies vacuum-only cleaning for the ERV core: do not get it wet. The factory MERV 6 filters are washable, but that does not make the core washable. It calls for filter care four times a year and core and cabinet cleaning twice a year, with exterior hoods inspected monthly. These are the manufacturer’s equipment-care requirements. Electrical power must be disconnected before cleaning or servicing as the manual directs. Follow the supplied instructions and use qualified assistance where the work requires it.
Electrical power and operating expectations
This ventilator requires a 120-volt, 60-hertz supply. Its published 77-watt figure is tied to a 64-CFM operating point; it is not a statement that electrical use stays fixed at every speed. Fan settings and operating time affect consumption. The power connection also distinguishes an operating ventilator from a passive opening in the wall.
During an electrical outage, normal powered ventilation is unavailable unless an appropriate backup arrangement supplies the equipment. The ERV is not an emergency ventilation system. Outdoor conditions, the building and any other equipment still need their own appropriate safety arrangements.
Sound is also a system consideration. Fan speed, duct routing, mounting and grille placement affect what is heard in occupied rooms. Sound in occupied rooms varies with fan speed, mounting and the connected ducts. A sensible layout takes the nearby living spaces into account along with the mechanical connections. We help with product selection and explain the installation so these everyday considerations stay connected to the equipment choice.
Comparing ventilation choices
The comparison below separates equipment purposes rather than ranking every home with the same answer. The required airflow, installation route and humidity needs determine which option fits. We help with that product choice and explain the installation, while keeping the exact model specifications visible.
| Option | Main function | Buying consideration |
|---|---|---|
| METRO XTR | Balanced air exchange with heat and water-vapour recovery | Compact low-profile format; match its rated airflow to the design |
| HRV | Air exchange with primarily sensible heat recovery | Use the exact model’s ratings and the home’s humidity needs |
| Exhaust-only fan | Removes air from a selected location | Does not provide this ERV’s paired recovery core and supply path |
| Furnace circulation | Moves air through the heating distribution system | Indoor circulation alone does not establish an outdoor ventilation rate |
When to consider replacing a ventilation unit
An existing unit with persistent operating faults, damaged components or inadequate performance deserves evaluation by a qualified professional. Age by itself is not a diagnosis. A dirty filter, obstructed outdoor hood or unsuitable control setting can affect operation without establishing that replacement is the right answer.
When replacement is the chosen next step, the old model’s capacity and connection layout provide useful context. Renovations and changes in occupancy can also change the ventilation discussion. We help select replacement equipment around the current home rather than copying a model number solely because it was already installed.
We explain the new installation and its scope before the order proceeds. The METRO XTR is a particular capacity and cabinet arrangement, not a universal replacement for all residential ERVs. A sound choice accounts for the required airflow and the available space, then connects those requirements to a practical installation plan.
ERV installation in Toronto and the GTA
We provide installation in Toronto and the GTA. Standard installation is included in the price, and we explain any additional work before you order. Our licensed and insured technicians carry out the installation, and free GTA delivery is part of the purchase.
Ordering can be done online, over the phone or through the website chat. Our experts help with product selection and explain the installation. After the order, an HVAC expert calls to confirm the details and arrange the installation date. That connects the product purchase with the practical work required at the property.
We keep the process clear from selection to handover. The price above includes the equipment, delivery and standard installation; a 3% transaction fee applies to credit-card payments. Our one-year installation labour warranty accompanies the manufacturer equipment coverage. We handle manufacturer registration free of charge, so that administrative step is part of the purchase rather than another task left with you.
Lifebreath warranty and our installation coverage
This residential ERV carries a five-year manufacturer warranty on the energy recovery core and a five-year replacement parts warranty. Those periods refer to the core and equipment components; they are not a five-year labour promise. The linked METRO manual and Lifebreath warranty information describe the manufacturer coverage.
Because we install it, you get the full Lifebreath manufacturer warranty, and we register it for you free of charge. This applies to our Ontario installations. We also provide our one-year installation labour warranty. The equipment warranty and installation labour coverage have distinct roles, and both are part of the installed purchase.
Keeping the manufacturer instructions with the equipment makes its operation and care information easy to find later. We present warranty protection as part of choosing the installed product, with the original manufacturer documents available for reference. No additional registration fee is added for us to complete that step.
Frequently asked questions
Yes. It is a residential ERV that exchanges indoor and outdoor air through a heat-and-moisture recovery core. Its role is separate from space heating and cooling.
No. The 140 CFM net supply rating is at 0.3 inches water gauge external static pressure. Installed airflow depends on the connected system and its setup.
No. It is a recovery-efficiency test result at 64 CFM and 0°C. It cannot be applied as a percentage reduction to the whole utility bill.
The current specification states that a drain is not required for this model. Follow the supplied installation instructions for the selected configuration.
Yes. The standard MERV 6 filters are washable. Follow the METRO manual for cleaning and disconnect electrical power before care work.
No. Ventilation exchanges air with outdoors; it does not guarantee dehumidification when the outdoor air is humid. ERV and dehumidifier functions are different.
Yes. The price above includes equipment, delivery and standard installation. We explain additional work before you order. A 3% transaction fee applies to credit-card payments.
Yes. We register it free of charge for our Ontario installations. Residential coverage is five years on the ERV core and five years on replacement parts, alongside our one-year installation labour warranty.
Yes. Phone orders can be arranged without a deposit. Online orders take a $100 deposit, with the remaining balance after installation. Our expert calls after ordering to arrange installation.
Product documents and ordering
The documents below provide the model specifications, installation reference, operating instructions and manufacturer warranty information. We help you choose the product and explain its installation so the next step is straightforward. Any other questions? Call us at (437) 223-9253. We’re always happy to help.
- METRO XTR specification sheet
- METRO installation, operation and maintenance manual
- Lifebreath warranty information
Furnaces
Garage Heaters
Air Conditioners
Air Handlers
Heat Pumps
Mini- Splits
Tank Water Heaters
Tankless Water Heaters
Combi-Boilers
Boilers
ERV (Energy Recovery Ventilators)
HRV (Heat Recovery Ventilators)
Humidifiers
Filter Cabinets