Reznor UDXC175: direct heat for commercial and industrial spaces
The Reznor UDXC175 is a suspended, gas-fired fan unit heater with 175,000 BTU/h input and 145,250 BTU/h rated heat output. It heats the space around it directly instead of sending warm air through household ductwork. For a suitable commercial or industrial work area, that creates a dedicated heating zone. Size 175 is not included in Reznor’s residential utility-heater listing and is not offered here for a residential garage.
We help you choose the heater around the building, its intended use and the available connections. The UDXC size 175 has Canadian commercial and industrial listing. Residential utility-heater listing covers only sizes 30 through 125, not size 175. This model is not for a residential garage, sleeping quarters or primary residential heating. That distinction is central to selecting this product, not a small detail after purchase.
Our approach brings the appliance and installation together. Standard installation is included and carried out by our licensed and insured technicians. We explain the installation requirements for the property and arrange the order around a suitable application, so the equipment choice fits how the space will actually be used.
- No hidden fees: the price above includes the equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee.
- Free GTA delivery and our one-year installation labour warranty.
- Order online with a $100 deposit and pay the remaining balance after installation, or order by phone without a deposit.
- After ordering, our HVAC expert calls to confirm the order and schedule installation.
UDXC175 specifications at a glance
The table separates the gas input from useful rated output and identifies the measurement conditions behind other figures. Reznor lists these ratings for elevations up to 2,000 feet. Dimensions describe the heater assembly, not the complete space required for installation, servicing, venting and protection from stored items or vehicles.
| Specification | UDXC175 |
|---|---|
| Manufacturer model | Reznor UDXC, size 175 |
| Heater type | Power-vented axial-fan gas unit heater |
| Gas input | 175,000 BTU/h |
| Rated heat output | 145,250 BTU/h |
| Thermal efficiency | 83% |
| Standard fuel | Natural gas; approved propane conversion available |
| Air volume | 2242 CFM |
| Sound rating | 52 dBA at 15 feet |
| Electrical supply | 115 V, single phase, 60 Hz |
| Full-load current / normal power | 3.8 A / 392 W |
| Maximum overcurrent protection | 15 A |
| Gas connection / vent collar | ½ inch / 5 inches |
| Overall width × depth × height | 38 3/16 × 48 7/16 × 20⅛ inches |
| Unit / shipping weight | 193 / 221 lb |
| Standard heat exchanger | TCORE2 titanium-stabilized aluminized steel |
| Manufacturer warranty | Ten-year heat exchanger, burner and flue collection box; five-year electrical and mechanical operating components |
Why choose a suspended commercial unit heater?
A commercial unit heater provides a dedicated heat source for a suitable work area without relying on a residential heating arrangement. The UDXC175 uses an axial fan to distribute warm air directly across the space, and its suspended installation keeps the appliance off the floor. This can be useful where parking, work surfaces and storage already compete for floor area.
The standard TCORE2 heat exchanger uses titanium-stabilized aluminized steel. A hinged access panel, visible operating-status indication and integrated control board are practical parts of the design. These features support access and operation; they are not a reason to overlook the ongoing professional care described in the manual.
We focus on whether this particular capacity and layout fit the project. A smaller heater can be the sensible choice when the heat loss is modest, while a different capacity is needed when the building requires more output. Choosing a model for its actual duty is more useful than buying the largest heater that fits the available corner.
Commercial and industrial use: not a residential garage heater
Reznor lists size 175 for commercial and industrial installations in Canada. Its separate residential utility-heater listing stops at size 125. The larger size is therefore not simply a more powerful residential-garage alternative. Intended use remains a model-specific requirement, even where the cabinets and product names look similar.
We help choose equipment for the actual application. A private residential garage needs equipment with the appropriate residential listing. A commercial workshop needs a heating arrangement suited to its processes, construction and ventilation. The name of a website category cannot expand the uses established by the manufacturer.
Sleeping quarters and primary residential heating are outside the intended use. Commercial listing is also not a general approval for hazardous workshops. Airborne contaminants, flammable materials, exhaust equipment and the way the work area is occupied all affect suitability. The application must be established before selecting the heater; a larger input number alone is not a reason to choose it.
Sizing around heat loss, doors and working conditions
A commercial work area’s floor area alone cannot establish its heating requirement. Insulation in the roof and walls, door construction, air leakage, ceiling height and the indoor temperature target all influence the heat needed on a cold day. An insulated interior work area and a tall, exposed industrial workshop of the same floor area can present very different heating loads.
The useful comparison for this model is its 145,250 BTU/h rated output against the calculated heat demand. The 175,000 BTU/h input number describes fuel energy entering the appliance. Using input as though it were delivered heat overstates the available capacity. We keep those two numbers separate when explaining the model.
Frequent overhead-door opening adds another practical consideration: heated air leaves and cold air enters. The pattern of use affects recovery between openings. There is no universal number of cars or square feet that guarantees this heater is the right size. We help with selection using the actual property requirements instead of attaching an unsupported coverage range to the model name.
Temperature setbacks and a cold workshop
This heater is intended for an appropriate maintained-temperature application. Reznor cautions against using it where the heated-space temperature is below 4°C / 40°F because low ambient conditions can cause condensation in the heat exchanger. A work area left to freeze and heated only occasionally is therefore a different application from a space kept within the manufacturer’s operating guidance.
That matters when choosing a thermostat routine. Deep setbacks that allow the building to become very cold are not interchangeable with ordinary temperature adjustments in a maintained space. Heating a cold concrete slab, tools and stored materials also takes more than simply warming the surrounding air.
We include the intended operating pattern in the product-selection conversation. If the goal is brief warmth in a space that remains unheated most of the winter, the equipment choice needs to address that use directly. This commercial unit is not presented here as an all-purpose solution for warming any frozen commercial space on demand.
Understanding 83% thermal efficiency
Thermal efficiency relates the rated heat output to the fuel input under the specified test conditions. For the UDXC175, 145,250 BTU/h output corresponds to 83% of its 175,000 BTU/h input. It is a useful equipment rating, but it is not a forecast that a building’s gas bill will fall by a particular percentage.
Actual fuel use reflects the heating load, indoor setpoint, weather, operating hours and how often the space loses warm air through open doors. Improving an overhead-door seal changes the building load; changing a thermostat schedule changes the demand. Those are separate influences from the heater’s published thermal efficiency.
We present the rating as one part of selecting a suitable installed system. A higher-capacity heater is not automatically more economical, and an efficient appliance still has to be matched to the space. Comparing equipment on output, application and installation requirements gives a more complete picture than looking at the efficiency figure alone.
Air circulation without household ductwork
The UDXC175 is the fan-type version of this unit-heater family. Its published air volume is 2242 CFM, moving heated room air through the front discharge. This is circulating airflow, not a fresh-air ventilation rating. The appliance does not replace a ventilation system or remove the need for appropriate air quality in the work area.
A fan unit heater is not intended to be connected to a duct system. Adding improvised ducts changes the air-delivery arrangement and is specifically prohibited by the manufacturer. This is an important difference from a central furnace designed around supply and return ducts.
Air needs a useful route through the space. Tall cabinets, partitions and shelving can intercept the discharge, leaving other areas less comfortable. We explain the installation layout as part of the product choice. The purpose is to direct heat into the intended area without treating the published airflow as a promise of equal temperature at every point in an obstructed work area.
Placement, access and overhead-door movement
The overall assembly measures 38 3/16 inches wide, 48 7/16 inches deep and 20⅛ inches high. Its assembly height helps describe the appliance, but cabinet measurements alone are not an installation envelope. The overall depth includes the rear assembly shown in the manufacturer drawing, while the cabinet body has its own smaller dimension. Using the complete assembly measurement avoids planning a location around the sheet-metal cabinet alone. Suspension, service access, the fan behind the cabinet, vent connections and clearances all take additional space.
An overhead door occupies different positions during its travel. Tracks, opening hardware, parked vehicles and roof framing also shape the available installation location. A spot that appears empty when the door is closed can be unsuitable once the door opens. The heater needs a permanent clear operating area, not just enough room to lift the cabinet into place.
Our product consultation addresses the location requirements before the order is finalized. The manufacturer’s clearance and mounting instructions govern the installation, including protection from contact with vehicles and stored objects. The 193 lb unit weight and 221 lb shipping weight are separate figures; neither replaces the need for suitable structural support and the specified suspension arrangement.
Power venting and combustion air are different paths
Power venting uses a powered venter to move combustion products into the approved vent system. It does not mean the heater can discharge exhaust into the building. Combustion products must travel outdoors through the correct vent arrangement, with the required terminal location and clearances.
In standard configuration, combustion air comes from the space around the heater. The building must provide the air required for combustion. A tightly enclosed work area or other equipment that exhausts indoor air can affect that arrangement. The gas appliance, ventilation and building enclosure need to work together.
We treat the vent route and combustion-air arrangement as part of installing the appliance, not as an optional finishing detail. The listed 5-inch vent collar is a connection dimension, not a universal pipe specification for every route. The manual determines the permitted vent materials, sizes and configuration for the actual installation.
When separated combustion becomes relevant
Reznor offers a separated-combustion conversion for the UDXC family. It is an optional configuration using the manufacturer’s conversion components and instructions, not a standard feature created by attaching an outdoor-air pipe to an ordinary unit. The standard and converted arrangements have different combustion-air requirements.
The distinction is particularly relevant where the indoor environment contains dust, dirt or airborne contaminants. Bringing suitable combustion air from outdoors can reduce exposure of the burner to contaminants in the room. It does not make a heater safe in every hazardous atmosphere or remove restrictions on flammable vapours.
We explain the required equipment configuration for the project rather than describing every optional accessory as included. Workshop processes and stored materials affect the choice. The stock product name by itself does not establish that a separated-combustion kit, terminal kit or specialized air-discharge accessory is part of the purchase.
Fuel and electrical connections
Natural gas is the standard fuel configuration, with an approved propane conversion available. Fuel conversion is professional work using the correct manufacturer kit and instructions. Natural gas and propane are not interchangeable merely because they both supply a flame. The appliance rating plate and installed configuration identify the fuel it is prepared to use.
The standard electrical supply is 115 V, single phase, 60 Hz. Reznor lists 3.8 A full-load current, 392 W normal power consumption and 15 A maximum overcurrent protection for size 175. Gas supplies the heating energy, while electricity operates the fan, venter and controls. The unit is not a power-outage heating appliance.
Our installation explanation covers the needed connections. The ½-inch gas connection is the valve connection size, not a design for the entire gas supply line. Pipe sizing involves the connected appliances and the supply arrangement. Safe electrical and gas work follows the manufacturer instructions and applicable Canadian requirements.
Controls and everyday comfort
Temperature control is part of using a dedicated heating zone. The selected thermostat needs to suit the unit’s actual controls and the space where it is installed. Optional controls listed for a whole product family are not necessarily standard equipment with every size. The exact ordering configuration establishes what is provided.
For size 175, Reznor publishes a 101,675 BTU/h low-fire output for the optional two-stage arrangement. That is distinct from the 145,250 BTU/h high-fire output. The presence of a low-fire figure in the family table does not mean every stocked unit includes the two-stage gas-control option. We establish the selected configuration as part of the order, and identify the thermostat and gas controls provided with the selected equipment.
A thermostat location needs to represent the area being heated. Direct discharge air, a cold exterior surface or the immediate draft from an opening door can give a different temperature reading from the working area. Good control placement and a sensible operating routine support comfort alongside the heater’s capacity.
Our technicians test the controls and show you how to run the new system. That handover concerns normal operation. The integrated status indication is useful operating information for a professional when attention is needed; it is not an invitation to bypass safety controls or carry out gas-component work.
Sound and comfort in a working space
Reznor publishes a sound level of 52 dBA at 15 feet for this size. Keeping the distance with the rating is important: a reading next to the cabinet is not the same measurement. Room surfaces and the installation location influence how operating sound is experienced inside a commercial workshop.
A fan heater moves air, so the character of the airflow matters alongside a sound figure. A workbench directly in the discharge path feels different from one reached by circulating room air. Mounting the unit with the working zone in mind helps connect the equipment layout to practical use of the room.
We explain those differences when helping choose the appliance. Published sound data is a comparison point, not a guarantee of silence in every building. Hard floors, metal doors and bare walls create a different acoustic environment from an acoustically treated work area, and equipment location remains part of planning the installed result.
Comparing practical heating approaches
The right comparison starts with the purpose of the space. A commercial unit heater, a central furnace and a portable heater are not simply different sizes of the same product. Their intended applications, installation methods and ways of distributing heat differ. We help keep that distinction clear when selecting equipment.
| Approach | Heat distribution | Selection consideration |
|---|---|---|
| UDXC175 unit heater | Fan moves warm air directly through a suitable commercial or industrial space | Requires gas, power, suspension, combustion air and outdoor venting |
| Central ducted furnace | Supply and return ducts serve a designed building system | Different equipment category and intended installation |
| Electric space heating | Varies with the selected electric appliance | Requires suitable electrical capacity and correct application rating |
| Separated-combustion configuration | Unit-heater circulation with dedicated outdoor combustion air | Requires the specified conversion and vent-terminal arrangement |
Replacing an existing commercial unit heater
A replacement is an opportunity to match the current use of the space, not just repeat the old input rating. Changes in doors, insulation, storage and working patterns can alter what is needed. The condition and arrangement of existing connections also matter when a different appliance is installed.
We help choose the replacement and explain the installation. Reusing a vent or mounting arrangement is not established by a similar-looking cabinet or matching fuel alone. The new equipment instructions govern the finished installation. That keeps the replacement decision grounded in compatibility rather than appearance.
Keeping the original product information available is useful for the comparison, but we carry the explanation of what the new installation requires. The aim is a clear plan for the heater, its location and its connections before ordering, with additional work identified upfront instead of becoming a surprise during installation.
Toronto and GTA installation with a clear order process
We install in Toronto and the GTA and provide free GTA delivery. The installed purchase brings equipment and standard installation into the price above. If the property needs work beyond a standard installation, we go over it with you before you order. That includes explaining what is needed for the product to suit the project.
Our expert calls after ordering to confirm the order and arrange installation. The conversation connects the chosen heater to the property requirements and scheduling. There is no need to translate a manufacturer parts diagram into an installation plan yourself.
Online ordering uses a $100 deposit, with the remaining balance after installation. Phone orders can be arranged without a deposit. We keep the payment route straightforward and disclose the 3% credit-card transaction fee alongside the installed-price commitment. The product price stays in the pricing area above so it remains consistent with the actual order.
Manufacturer warranty and our installation coverage
Reznor’s UDXC coverage includes a ten-year non-prorated warranty on the heat exchanger, burner and flue collection box assembly, plus five years on electrical and mechanical operating components. These are equipment-component periods, not a ten-year labour promise. The current manufacturer certificate is linked below for the complete warranty information.
Because we install it, you get the full Reznor manufacturer warranty, and we register it for you free of charge. This applies to our Ontario installations. We also provide our one-year installation labour warranty, so the installation protection is stated distinctly from the manufacturer’s component coverage.
We make the warranty information part of the installed-product explanation. Keeping the model, serial information and manufacturer literature with the equipment makes the correct product reference available later. Our free registration commitment does not add a charge to the purchase or turn optional accessories into standard equipment.
Care, safe storage and continued operation
The manufacturer calls for inspection and cleaning at the start of each heating season under normal conditions, with more frequent attention in unusually dirty air. Its service checklist includes the burner, heat exchanger, venting, fan and safety-related components. A qualified service professional performs that work following the manual.
Ordinary use also needs an unobstructed operating area. Storage arrangements change over time, particularly in working spaces. Boxes, suspended items and newly installed shelving must remain outside the required clearances and airflow paths. Gasoline and other flammable vapours or liquids must be kept away from the appliance.
The installation and operating manual is the reference for safety instructions and professional care. This product page explains the purchase and intended use, not gas adjustments or service procedures. Keep the manual accessible near the equipment so its model-specific operating and safety information remains available.
Frequently asked questions
No. Size 175 has commercial and industrial listing. Reznor’s residential utility-heater listing covers only sizes 30 through 125. This model is not intended for sleeping quarters or primary residential heating.
No. That is the gas input. Rated heat output is 145,250 BTU/h, with 83% thermal efficiency.
No. The UDXC is a direct-discharge fan unit heater and must not be attached to a duct system.
No. The standard power-vented unit uses indoor combustion air. Separated combustion requires the specified conversion kit and terminal arrangement.
No. Reznor cautions against applications where the heated-space temperature is below 4°C / 40°F. The operating pattern needs to suit that requirement.
Yes. It needs a 115 V, single-phase, 60 Hz supply for its fan, venter and controls. It does not provide heat during a power outage.
Yes. Equipment, delivery and standard installation are included. We explain extra work before you order, and credit-card payments carry a 3% transaction fee.
Yes. We register the full manufacturer warranty free of charge for our Ontario installations. We also provide a one-year installation labour warranty.
Yes. Ordering by phone provides a route without a deposit. Online orders take a $100 deposit, with the remaining balance after installation.
Product documents and your next step
The manufacturer documents below cover specifications, installation, operation, care and warranty. We help you select the heater and explain its installation for the intended space. Any other questions? Call us at (437) 223-9253. We’re always happy to help.
- Reznor UDXC technical specifications
- Reznor UDXC installation and operating manual
- Reznor manufacturer warranty
Furnaces
Garage Heaters
Air Conditioners
Air Handlers
Heat Pumps
Mini- Splits
Tank Water Heaters
Tankless Water Heaters
Combi-Boilers
Boilers
ERV (Energy Recovery Ventilators)
HRV (Heat Recovery Ventilators)
Humidifiers
Filter Cabinets
Air Purifiers