AprilAire 800: whole-home steam humidification for a ducted system
The AprilAire 800 is an electrode steam humidifier that delivers moisture through a dispersion tube connected to the home’s ductwork. Its published output ranges from 11.5 to 34.6 US gallons per day, with capacity determined by the configured electrical supply and current setting.
This is a steam-generating appliance, rather than a bypass evaporative humidifier. It boils water inside a replaceable canister and uses the HVAC blower to distribute the resulting moisture. We explain the water, electrical, duct and control requirements alongside the amount of humidity the home needs.
- Installation included: we supply the humidifier with standard installation included in the price above.
- No hidden fees: the price above includes equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee.
- Free GTA delivery: we deliver your equipment in the GTA at no charge.
- Warranty: AprilAire provides a five-year limited equipment warranty. We provide our one-year installation labour warranty and register the manufacturer warranty free of charge.
- Payment options: order online with a $100 deposit and pay the remaining balance after installation. For a phone order, we can arrange delivery without a deposit.
- Any other questions? Call us at (437) 223-9253. We’re always happy to help.
AprilAire 800 specifications and configured output
| Specification | Model 800 |
|---|---|
| Exact model and type | AprilAire 800; electrode canister steam humidifier |
| Published steam output range | 11.5–34.6 US gallons per day, according to voltage and current setting |
| Output at 120 V, 11.5 / 16 A | 11.5 / 16.0 US gallons per day |
| Output at 208 V, 11.5 / 16 A | 20.5 / 30.0 US gallons per day |
| Output at 240 V, 11.5 / 16 A | 23.3 / 34.6 US gallons per day |
| Electrical supply options | 120, 208 or 240 VAC; 60 Hz; single phase |
| Cabinet width × height × depth | 10⅛ × 20⅞ × 7⅛ inches |
| Unit-only / operating weight | 23 / 27 lb |
| Supply water | Cold water; suitable hard, soft or softened water |
| Published supply conductivity / pressure | 125–1,250 µS/cm / 25–120 psi |
| Supply / drain connection | ¼-inch copper compression / ⅞-inch flexible drain hose connection |
| Humidity control | Model 62 Automatic Digital Humidifier Control |
| Distribution | Steam dispersion tube in suitable ductwork with HVAC blower operation |
| Manufacturer equipment protection | Five-year limited warranty |
| HVAC Market protection and registration | One-year installation labour warranty; free manufacturer warranty registration |
| Manufacturer recommended coverage | Tight construction, 8-foot ceilings, 16 A: up to 6,000 sq. ft. at 208/240 V; up to 3,500 sq. ft. at 120 V |
In a tightly built home, AprilAire recommends the Model 800 for up to 6,000 square feet at 208 or 240 V on the 16 A setting, or up to 3,500 square feet at 120 V on the 16 A setting. These maximum recommended home sizes assume 8-foot ceilings. The installation manual lists lower coverage for average or loose construction and for the 11.5 A setting. The appropriate configuration follows the home’s moisture load and available electrical supply.
Gallons per day describe moisture-production capacity, not a water-storage tank size. The selected electrical arrangement determines the published output. We explain the installation and configured capacity together so the maximum rating is not mistaken for every installation’s output.
Why choose the AprilAire 800?
This model is useful to consider when a home needs steam humidification distributed through suitable ducts. Its main buying features connect moisture output, controls and the installation arrangement:
- Electrode steam generation: electrical current heats the water inside the canister.
- Configurable capacity: documented output options let the equipment be matched to the application.
- Automatic humidity control: the Model 62 control coordinates a humidity call with the HVAC blower.
- Ducted distribution: a dispersion tube introduces steam into the air stream.
- Status indicators: illuminated indicators describe operating conditions and canister attention.
- Purchase support: we explain the equipment and installation, handle free warranty registration and provide our one-year installation labour warranty.
The configured electrical output needs to match the home’s moisture requirement and the distribution airflow available from its HVAC system. Steam generation provides a different operating method from an evaporative water panel. The useful choice follows the building, water supply, electrical capacity and practical distribution arrangement.
Sizing a whole-home humidifier: moisture demand and air leakage
A humidifier is selected for the amount of moisture the building needs, rather than floor area alone. The home’s air leakage, ventilation, ceiling height, outdoor conditions and desired indoor humidity all affect that requirement. The Model 800’s configured output describes the available production, while the building’s air exchange and moisture sources shape the amount actually needed.
A tightly built home retains moisture differently from a home with substantial air leakage. Two houses with the same floor area can therefore require different humidification capacities. Ventilation and exhaust systems also move indoor air out and bring replacement air into the building.
Household activities add moisture as well. The resulting indoor humidity reflects both that moisture and the rate at which the building exchanges air. A larger humidifier is not automatically the right answer to every complaint about dry indoor conditions.
The distribution system matters too. The ductwork, blower operation and dispersion-tube arrangement need to carry moisture into the intended spaces. The required moisture delivery needs a suitable electrical configuration and enough connected airflow to absorb it. Floor area alone does not describe the building’s air exchange or its distribution system.
How electrode steam generation works
Two electrodes extend into water inside the steam canister. Electrical current flowing through the water causes it to boil, producing steam. Water conductivity is part of that process, so the water supply is an equipment-selection consideration as well as a plumbing connection.
Fill and drain valves work together to manage the water level and conductivity. The control board coordinates operation in response to humidity demand. Steam travels through the approved hose or piping arrangement to the dispersion tube, where the moving duct air carries the moisture onward.
The canister is a replaceable operating component. Mineral accumulation and water conditions affect its useful operating period. It is not a permanent tank that can be ignored once the equipment has been installed. The canister’s replacement requirement belongs alongside its moisture output when comparing ongoing ownership with an evaporative Water Panel system.
The steam system does not rely on a wetted evaporative panel in the furnace air stream. It does still need appropriate air movement and absorption space for distribution. Making steam and distributing it through the home are connected parts of the same installation.
Electrical configuration: why maximum output varies
The manufacturer publishes six output combinations. At 120 V, the 11.5 A setting produces 11.5 US gallons per day and the 16 A setting produces 16.0. At 208 V, the corresponding figures are 20.5 and 30.0 US gallons per day.
At 240 V, published output is 23.3 US gallons per day at 11.5 A and 34.6 at 16 A. These figures explain why the maximum capacity cannot be assigned to every Model 800 installation. The supply, current setting and application need to form an appropriate arrangement.
Electrical design includes the required circuit, overcurrent protection, disconnecting provisions and connections under the manufacturer’s instructions and applicable requirements. The appliance’s operating current is not a substitute for selecting all those components correctly.
We explain the proposed electrical arrangement and any work beyond standard installation before you order. Choosing a larger output setting also changes electricity use during operation. The electrical circuit and current setting support the chosen output. The humidity control then requests operation as needed instead of keeping that output running continuously.
Automatic humidity control and HVAC blower coordination
The Model 62 Automatic Digital Humidifier Control measures humidity in the duct arrangement described by the manufacturer. A call for humidity coordinates humidifier operation with the connected HVAC system. The blower activation function can request air movement while the furnace or air handler is otherwise in standby.
The outdoor temperature sensor and configured control settings support automatic adjustment. Indoor humidity that is reasonable in milder weather can produce condensation on colder surfaces during a severe cold spell. Control setup therefore needs to suit the home as well as the humidifier.
A digital display and operating indicators provide information about the system’s normal state. Those indicators do not replace an appropriate response to a leak, recurring fault or abnormal operation. Technical attention follows the manufacturer’s instructions through qualified professionals.
We explain the selected controls and show you how to run the system. A replacement humidifier also needs its control connections assessed as part of the proposed installation. An existing thermostat or humidistat is not assumed to provide every required function simply because it already controls another appliance.
Relative humidity, winter settings and condensation
Relative humidity describes moisture in the air in relation to the amount that air can hold at its temperature. A humidity setting is therefore connected with temperature and the building’s surfaces. More moisture is not always the right target.
Cold windows or other cold surfaces can develop condensation when indoor moisture is too high for those conditions. The manufacturer’s operating guidance calls for suitable settings and attention to condensation. Raising the control continuously is not a remedy for every comfort concern.
Normal operation aims for controlled moisture delivery within the conditions that the home’s windows, surfaces and distribution system can accommodate. A room that feels dry can also be affected by temperature, air leakage or air movement. Keeping the humidity objective clear helps distinguish the humidifier’s role from unrelated building or heating problems.
The humidifier adds moisture; it is not a dehumidifier or an air cleaner. It does not remove an existing source of excess moisture, correct a water leak or establish a medical outcome. Product selection focuses on controlled moisture delivery and the conditions the home can accommodate.
Water supply, conductivity and canister selection
The Model 800 uses cold supply water. The published supply-water conductivity range is 125–1,250 µS/cm, with pressure of 25–120 psi. Conductivity measures how readily water carries electrical current, which matters because current through the water creates the steam.
The installation instructions discuss suitable hard, soft and softened water and different canister arrangements. The standard Model 80 canister and the lower-conductivity Model 80LC arrangement have different applications depending on water and voltage. Their names are not interchangeable descriptions of every installation.
Water chemistry can affect startup behaviour, draining and canister life. A water-softening system does not by itself establish the best canister arrangement. Likewise, purified water is not automatically an improvement for an electrode humidifier that needs appropriate conductivity.
Water conductivity, supply pressure and the selected canister arrangement each influence the electrode process and the equipment’s operating response. The goal is suitable operation with the actual supply, rather than an unsupported promise that the same configuration works with every water source or treatment system.
Steam dispersion and duct absorption space
The dispersion tube introduces steam into a suitable part of the duct system. The manufacturer’s tubelet design directs steam into the air stream and manages condensed moisture around the tube. Airflow and placement still need to allow the steam to be absorbed.
Absorption distance changes with air temperature, airflow and the amount of steam introduced. Nearby turns, filters, coils or other obstructions affect where the tube can be placed. A short distance that works in one duct arrangement is not a universal installation dimension.
The steam connection route also matters. Proper routing and slope manage condensation that forms along the path. A hose installed with an unsuitable sag or route can interfere with the intended movement of steam and condensate.
The cabinet location and dispersion-tube position are linked by the steam route. That route needs the specified material and slope to manage condensate. The equipment cabinet is only one part of the installation space. Practical duct access and the manufacturer’s airflow and control provisions remain part of the complete plan.
Cabinet location and access
The cabinet measures 10⅛ inches wide, 20⅞ inches high and 7⅛ inches deep. Its unit-only weight is 23 lb, with a published operating weight of 27 lb. Those figures describe the equipment; the mounted installation also needs appropriate support, clearances and connection access.
The manufacturer describes duct-mounted and remote-mounted arrangements. The suitable location depends on the duct connection, water supply, electrical route and drain. Access to the canister and other components needs to remain practical throughout ownership.
A compact cabinet does not mean the unit can occupy any spare wall space. Steam routing, drainage and service access place requirements on the surrounding installation. We explain those requirements with the proposed location and any extra work before you order.
Water connections, automatic draining and condensate
The supply connection is a ¼-inch copper compression fitting, and the drain connection is sized for a ⅞-inch flexible drain hose. The drain arrangement needs to follow the manufacturer’s requirements and suit the building’s plumbing route.
The humidifier uses cold inlet water to temper the water discharged during draining. The manufacturer limits drain-water temperature to 140°F. That tempering function does not remove the need for an appropriate drain connection and suitable materials.
Automatic filling and draining support conductivity management during operation. After 72 hours without a humidity call, the documented end-of-season function drains the canister and places the unit in standby. Automatic operation is different from being maintenance-free.
Water, drainage, electrical power and steam distribution serve separate functions in the installation. All need appropriate connections for the humidifier to operate as intended. A new unit’s connection route can differ from that of an older evaporative humidifier. The complete arrangement needs to suit the selected steam equipment.
Compatibility with furnaces, air handlers and other systems
The Model 800’s normal ducted arrangement uses the HVAC blower to distribute moisture. The heating appliance does not need to provide all the heat that generates the steam, because the humidifier creates steam electrically. Suitable distribution airflow remains necessary.
A furnace, compatible air handler or appropriately controlled ducted system presents a different installation from a building without distribution ducts. The manufacturer describes separate fan-pack arrangements for applications that need them. A fan pack is not assumed to be included with this Model 800 purchase.
Control wiring, blower coordination, airflow proving and high-limit provisions need to follow the intended application. A new humidifier can involve more than connecting the two wires used by an older accessory. The connected HVAC equipment needs the controls and airflow provision appropriate to the selected humidifier arrangement.
The humidifier does not increase a furnace’s heating output or an air conditioner’s cooling capacity. Its role is moisture delivery. Keeping those functions distinct makes the equipment comparison more useful when several comfort concerns occur in the same home.
Compare steam, bypass and fan-powered humidifiers
| Design | How moisture is produced | Useful installation comparison |
|---|---|---|
| This electrode steam model | Electrical current boils water inside a canister | Electrical capacity, water conductivity, steam distribution and drainage |
| Bypass evaporative | Air moves through a wetted water panel | Suitable bypass airflow path, available heat, water and drain arrangement |
| Fan-powered evaporative | An integral fan moves air through a wetted panel | Mounting space, electrical supply, water, drainage and distribution conditions |
| Portable room humidifier | Output and operating method vary by model | Serves its local space with its own filling and care requirements |
The designs differ in how they generate moisture and move it into the central duct air. Moisture demand and the existing distribution system shape the choice. Steam output, evaporative capacity and a room unit’s label describe different operating arrangements. The best comparison includes installation work and ongoing manufacturer care alongside output.
A higher published maximum is useful only when the home and installation can use that capacity. The appropriate design also needs suitable controls and a practical maintenance arrangement. The comparison includes the water requirement, electrical configuration and duct connection of each design. Those requirements differ even when two models have similar daily moisture ratings.
Signs to consider replacement or a different humidifier design
Persistent inadequate humidity, recurring operating faults, leakage or an unsuitable distribution arrangement can prompt a replacement discussion. These symptoms have different causes. An operating problem deserves appropriate qualified attention rather than an automatic assumption that a larger humidifier is required.
Changes to ventilation, insulation, HVAC equipment or how the home is occupied can also change humidification needs. A change to air leakage, ventilation or occupancy can alter moisture demand even while the home’s floor area stays the same. The existing unit’s nameplate and configuration provide context for comparing a replacement.
For an older Model 800, a Canadian safety recall covers specified units made between June 2010 and January 2015 with D-shaped electrode connector wires. If an existing unit is covered, stop using it and follow the manufacturer’s recall process. The Health Canada recall notice identifies the affected equipment and action.
Humidifier installation in Toronto and the GTA
Start with one call to HVAC Market and tell us about the home, existing HVAC system and humidity concern. Our experts help you choose the equipment and explain the installation process. A steam replacement and a first whole-home humidifier can involve different connection work.
We bring the cabinet location, electrical configuration, water supply, drain, steam route and duct distribution into the discussion. If the home needs anything beyond standard installation, we go over it before you order. You are not left to translate the specifications into an installation plan alone.
We supply the humidifier with standard installation included, using licensed and insured technicians. Free GTA delivery is included. We also offer free removal and disposal of the old unit, with the replacement arrangement explained alongside the work.
After you order, one of our HVAC experts calls to confirm the order and schedule installation. Online ordering uses a $100 deposit, with the remaining balance after installation. Prefer a phone order? We can arrange delivery without a deposit.
Our technicians test the controls and show you how to run the new system. We also register the manufacturer warranty free of charge. Keep the equipment records with the model, serial number and installation details so the purchased appliance and its configuration remain identifiable.
Manufacturer care: canister and electrode wires
The manufacturer calls for annual replacement of the canister and O-ring, annual cleaning of the drain valve and fill-valve screen, and annual inspection of the electrode wires. The electrode wires are replaced every three years or as needed under the instructions.
The actual operating environment and water conditions also matter to canister attention. Status indicators help identify the unit’s operating condition, but they do not authorize bypassing a protective function or continuing to restart a system with an unresolved problem.
Hot water, steam and electrical energy require the manufacturer’s shutdown and safe-work procedures. Technical care follows the instructions through appropriate qualified professionals. This is different from treating the canister as a reusable water panel or applying the maintenance routine from an evaporative model.
The linked manufacturer instructions identify the technical care applicable to this electrode system. Ongoing inspection, maintenance and repairs follow the manufacturer’s instructions through appropriate professionals. Access for that attention needs to remain available after installation.
Manufacturer warranty for our Ontario installations
When we install it, you get the full AprilAire manufacturer warranty, and we register it for you free of charge.
AprilAire provides a five-year limited equipment warranty for defects in materials or workmanship. The manufacturer’s equipment protection is different from routine consumable replacement or installation labour coverage. The current written warranty policy is linked with the product documents.
We register the manufacturer warranty for you, free of charge. Registration keeps the purchased product identified in the manufacturer’s process; it is not a promise of a longer equipment warranty than the stated coverage.
We provide our one-year installation labour warranty. We explain the equipment and installation protection clearly with the purchase. Any other questions? Call us at (437) 223-9253. We’re always happy to help.
Frequently asked questions
No. The maximum published output is 34.6 US gallons per day at 240 V and the 16 A setting. Other voltage and current combinations have different published outputs.
No. The Model 800 uses electrical current through water in a canister to generate steam, which is distributed through a suitable duct arrangement.
No, not in its normal ducted arrangement. Appropriate blower operation and steam absorption space are needed. A non-ducted application requires a different approved distribution arrangement.
Yes. The Model 800 uses suitable cold supply water, including water used for drain tempering. Conductivity, pressure and the canister arrangement need to suit the application.
No. Electrode steam generation needs suitable water conductivity. Water treatment and canister selection need to follow the manufacturer’s guidance.
Yes, with the appropriate blower activation and control arrangement. The steam humidifier generates heat electrically while the HVAC blower provides distribution airflow.
Yes. The price above includes equipment, delivery and standard installation, with free GTA delivery. A 3% transaction fee applies to credit-card payments. We explain extra work before you order.
Yes. When we install it, you get the full AprilAire manufacturer warranty, and we register it for you free of charge. AprilAire provides a five-year limited equipment warranty, and we provide our one-year installation labour warranty.
No. The manufacturer calls for annual canister and O-ring replacement and other specified care, including electrode-wire inspection and periodic replacement.
Order online with a $100 deposit and pay the remaining balance after installation, or call to arrange a phone order without a deposit. Our HVAC expert calls after the order to confirm it and schedule installation.
Product documents
Keep the Model 800 specifications, operating instructions and warranty policy with the equipment records.
- Current Model 800 specification sheet (January 2026)
- Model 800 installation and maintenance instructions
- Model 800 English and French owner’s manual
- Manufacturer humidifier warranty policy
- Spec Sheet – Aprilaire Humidifier (original product document)
- Owner Manual – Aprilaire Humidifier 500-700 (original evaporative-model reference)
- Installation Guide – Aprilaire Humidifier 800 (original product document)
- Owner Manual – Aprilaire Humidifier 800 (original product document)
Furnaces
Garage Heaters
Air Conditioners
Air Handlers
Heat Pumps
Mini- Splits
Tank Water Heaters
Tankless Water Heaters
Combi-Boilers
Boilers
ERV (Energy Recovery Ventilators)
HRV (Heat Recovery Ventilators)
Humidifiers
Filter Cabinets
Air Purifiers