Lennox MWLD024S6S-1P with MWMD024S6-1P: 2-ton cold-climate ductless heat pump
The Lennox MWLD024S6S-1P is a two-ton single-zone ductless heat pump that heats and cools one space. It is paired with the Lennox MWMD024S6-1P high-efficiency wall-mounted indoor unit, uses R-32 refrigerant, and is rated by Lennox at 20.0 SEER2 for cooling and 9.5 HSPF2 for heating, with heating operation down to −22°F (−30°C).
This matched pair delivers a rated 22,000 BTU/h of cooling and 25,000 BTU/h of heating. It is a strong fit for a large open main floor, a big great room or a well-insulated open basement, especially where there are no ducts or where the existing system leaves one area too hot in summer and too cool in winter.
Installation included: we supply this system with standard installation included in the price above.
No hidden fees: the price above includes equipment, delivery and standard installation. Credit-card payments carry a 3% transaction fee.
Free GTA delivery: we deliver your equipment in the GTA at no charge.
Warranty: Lennox covers the compressor for seven years and other covered components for five years. With our installation, the full Lennox manufacturer warranty applies, we register it at no charge, and we add our one-year installation labour warranty.
Payment options: order online with us using a $100 deposit and pay the remaining balance after installation. For a phone order, we can arrange delivery without a deposit.
Any other questions? Call us at (437) 223-9253. We're always happy to help.
MWLD024S6S-1P and MWMD024S6-1P matched-pair specifications
The figures below come from Lennox's product specifications for the MWLD outdoor units (August 2025) and the MWMD wall-mounted indoor units (December 2025). Lennox lists this exact combination as an AHRI-rated, ENERGY STAR certified system match.
| Specification | MWLD024S6S-1P / MWMD024S6-1P |
|---|---|
| Outdoor / indoor unit | MWLD024S6S-1P / MWMD024S6-1P |
| System type | Single-zone ductless heat pump: one outdoor unit, one wall-mounted indoor unit |
| Rated cooling / heating capacity | 22,000 / 25,000 BTU/h (AHRI rating conditions) |
| Nominal size | 2 tons |
| SEER2 / EER2 | 20.0 / 12.80 |
| HSPF2 (Region IV) | 9.5 |
| AHRI reference (listed by Lennox) | 216411309 |
| ENERGY STAR | Certified (matched system, per Lennox) |
| Heating capacity at 70°F indoor | About 24,400 BTU/h at 5°F (−15°C); about 11,600 BTU/h at −22°F (−30°C) |
| Operating range, heating / cooling | −22°F to 75°F (−30°C to 24°C) / 0°F to 115°F (−18°C to 46°C) |
| Indoor sound, low / high fan | 28 / 47 dBA |
| Outdoor sound, cooling | 54 dBA (36 in in front, 60 in high) |
| Refrigerant | R-32, factory charge 4 lb 8 oz |
| Compressor | Variable-frequency BLDC rotary, inverter driven |
| Electrical | 208/230 V, 1 phase, 60 Hz; MCA 21 A; MOCP 30 A |
| Refrigerant lines, liquid / gas | ¼ / ⅝ in flare |
| Maximum line length / height difference | 98 ft / 66 ft |
| Indoor airflow, turbo (cooling) | 711 cfm |
| Indoor unit W × H × D / net weight | 41½ × 11¾ × 8½ in / 28 lb |
| Outdoor unit W × H × D / net weight | 37 × 39⅜ × 15⅛ in / 150 lb |
| Lennox warranty | Compressor 7 years; other covered components 5 years; accessories and controls 1 year |
| HVAC Market | Standard installation included; one-year installation labour warranty; free warranty registration |
Why choose the Lennox MWLD024S6S-1P?
Real cold-climate heating. Lennox rates the MWLD outdoor units for heating operation down to −22°F (−30°C), and its heating table for this pair still shows about 24,400 BTU/h at 5°F (−15°C). That figure is the one to look at for an Ontario winter.
High efficiency both ways. At 20.0 SEER2 and 9.5 HSPF2, this pair is part of an MWLD family rated up to 25.0 SEER2 and 11.0 HSPF2, and it is ENERGY STAR certified as a matched system.
Quiet indoors. Lennox publishes 28 / 47 dBA (low / high fan) for the MWMD024S6-1P, and its Calm Air mode cools through thousands of micro holes in the front panel with the louvres closed, so there is no cold draft blowing on you.
Smart controls included. The indoor unit has built-in Wi-Fi for the SmartThings app, a motion-detection sensor, and a rechargeable wireless remote controller that comes with every indoor unit.
Built for winter. The outdoor unit has a base-pan heater against ice build-up, a compressor crankcase heater and automatic defrost, all from the factory.
Easy to live with. The indoor unit's Freeze Wash function frosts the indoor coil, melts the ice and dries the coil to wash away dust, and the washable one-micron filter slides out for cleaning following the owner's manual. An LED readout on the unit shows the operating status at a glance.
What size space can the MWLD024S6S-1P heat and cool?
HVAC Market recommends this capacity class for approximately 1,200–1,500 sq. ft. under suitable conditions. Treat that range as a planning guide, not a heat-loss calculation. It reflects a reasonably insulated space with typical ceiling height, windows and occupancy.
The rated output gives the range its backing: 22,000 BTU/h of cooling and 25,000 BTU/h of heating at the standard AHRI rating conditions. In the coldest weeks, output follows the outdoor temperature, which is why the cold-climate figures further down this page matter as much as the headline number.
Several things move a space up or down that range: large or west-facing windows, cathedral ceilings, an older uninsulated wall, a basement with exposed foundation walls, or a kitchen with heavy cooking loads. Open layouts let one wall-mounted unit reach more of the floor; separate closed rooms behind doors reduce what a single head can serve.
We help you choose between neighbouring sizes before you order. If the space sits at the edge of this range, we look at the rooms, windows and existing heat with you, so the 2-ton pair is chosen for the real load and not only the floor area.
Inverter compressor explained
The MWLD outdoor unit uses a variable-frequency, brushless DC rotary compressor driven by an inverter. Instead of switching fully on and fully off, it speeds up when the room is far from the set temperature and slows down to hold it there.
That steady operation brings practical benefits. Room temperature stays more even, there are fewer noisy start-ups, and the system spends much of its time at low speed, which is where it is most efficient. The electronic expansion valve adjusts refrigerant flow to match the compressor speed.
Lennox lists a set of protections around the compressor: discharge-temperature monitoring, overcurrent protection, condenser high-temperature protection, voltage protection and a three-minute restart delay. These keep the compressor inside its safe range when it is very hot or very cold outside.
For you, the result is simple: set the temperature you want and let the system modulate. Constantly turning a mini-split off and on, or making big setpoint swings, works against what the inverter does best.
Cooling efficiency: SEER2 and EER2
SEER2 measures cooling efficiency over a typical season; EER2 measures it at a single hot condition (95°F outdoors). Lennox lists this pair at 20.0 SEER2 and 12.80 EER2, under AHRI Standard 210/240-2023.
Higher numbers mean more cooling for each unit of electricity. Compared with older equipment, a 20.0 SEER2 system can noticeably reduce the electricity used for summer cooling, though your actual bill follows your electricity rate, how warm you keep the space, and how many hours the system runs.
HSPF2 is the heating counterpart. At 9.5 HSPF2 (Region IV rating), this pair heats efficiently through the shoulder seasons and much of the winter. Lennox notes that dividing by 1.15 converts the rating to the colder Region V basis used for comparison in northern climates.
Ratings are comparison tools. They let you compare one system against another on equal terms; they are not a promised dollar saving.
Cold-climate heating for Ontario
Lennox rates the MWLD outdoor units for heating operation from −22°F to 75°F (−30°C to 24°C) outdoors. An operating limit is not the same as full output at that temperature, so the capacity table is the better guide.
For this exact pair, with the room at 70°F, Lennox's heating-capacity table lists about 24,400 BTU/h at 5°F (−15°C) and about 11,600 BTU/h at −22°F (−30°C). Output falls as the outdoor air gets colder, while the home's heat loss rises, so the coldest nights are where the plan is decided.
On the coldest nights of an Ontario winter, a space loses heat fastest while the outdoor unit has the least output. A space whose heat loss on those nights is higher than the system's output at that temperature needs some supporting heat.
The MWMD indoor unit includes an external heat function for exactly that: it can operate a third-party heat source as supplemental or emergency heat, lock out the compressor below an outdoor temperature you set, or run the backup heat during defrost. Keeping existing baseboards or another heat source as backup is a common, sensible plan.
Can it replace electric baseboard heating?
Often, yes, for the space it serves. A heat pump moves heat instead of making it from resistance, so in mild and moderate weather it uses less electricity than baseboards for the same heat. With 9.5 HSPF2 and cold-climate output, this pair can carry most of a typical heating season.
Two things decide how far it goes. First, the wall-mounted unit heats the room it is in and the areas air can reach from it; separate bedrooms behind closed doors keep needing their own heat. Second, on the coldest nights the system's output may fall below the room's heat loss.
For many homes the best result is a combination: the mini-split does most of the work, and the baseboards stay in place and switch on only when needed. The indoor unit's external heat function can coordinate a compatible backup heat source.
We help you plan which rooms the system can cover and where existing heat stays. That way, removing baseboards is a decision based on the space, not a guess.
Quiet operation
Lennox publishes 28 / 47 dBA for the MWMD024S6-1P indoor unit at low and high fan speed. The low figure makes the unit a comfortable choice for bedrooms and offices.
For the MWLD024S6S-1P outdoor unit, Lennox lists a cooling sound pressure of 54 dBA, measured in an anechoic room with the microphone 36 inches in front of the unit at a height of 60 inches. Real-world sound depends on nearby walls, fences and hard surfaces, which can reflect it.
The indoor unit has four fan speeds (low, medium, high and turbo) plus a Quiet setting and a Good Sleep timer on the remote. Calm Air mode closes the louvres and sends air through the micro-perforated panel, which also lowers airflow noise in cooling.
Placement makes a difference outdoors. We install the outdoor unit with its clearances in mind and away from bedroom windows and patios where practical, so the sound you hear stays low.
Controls: Wi-Fi, remote, motion sensor and comfort modes
Every MWMD024S6-1P comes with a wireless remote controller that recharges by USB-C or by the solar panel on its back. It runs Auto, Cool, Dry, Fan and Heat modes, sets the temperature in one-degree steps, and controls fan speed, louvre direction and timers.
The indoor unit has built-in Wi-Fi. Through the SmartThings app you can control the system from your phone, use voice control through supported assistants, set schedules and automations, use geo-fencing to switch modes when you leave or arrive, and view energy-use estimates. The Lennox Home app integrates with SmartThings as well.
A motion-detection sensor lets you choose whether the airflow follows you or avoids you, and it can switch to energy-saving operation when the room is empty. AI Auto mode, used with the app, learns the room's patterns and adjusts operation automatically.
Lennox also offers a touchscreen wired controller, a programmable wired controller and a thermostat adaptor for any 24V thermostat as optional accessories, sold separately.
R-32 refrigerant
This system uses R-32, a single-component refrigerant with zero ozone-depletion potential and a much lower global-warming potential than the refrigerant used in many older systems. It also transfers heat efficiently, which helps the high SEER2 and HSPF2 ratings.
R-32 is classed A2L: low toxicity and lower flammability. Equipment designed for it uses its own components and procedures, so it cannot be mixed with other refrigerants. The MWLD024S6S-1P is factory pre-charged with 4 lb 8 oz of R-32.
Refrigerant work is done only by licensed technicians. Our technicians handle the line set, vacuum, leak test and charge according to Lennox's instructions for this exact pair.
Because R-32 is the direction the industry is moving, choosing it now also means current equipment and a refrigerant with a long future, rather than a phase-down refrigerant.
Indoor and outdoor unit design, including winter placement
The MWMD024S6-1P indoor unit measures about 41½ × 11¾ × 8½ inches (width × height × depth) and weighs 28 lb. It mounts horizontally high on a wall using the wall plate supplied, with refrigerant connections from the left, right or rear. Its built-in filter captures particles as small as one micron and is washable and reusable.
The MWLD024S6S-1P outdoor unit measures about 37 × 39⅜ × 15⅛ inches overall (width × height × depth) and weighs 150 lb net. Its cabinet is heavy-gauge steel with tabs for secure mounting, an aluminium-fin, copper-tube coil and a direct-drive fan.
Winter placement matters in Ontario. The outdoor unit needs to sit above the expected snow line and away from roof drip lines, on a pad, stand or wall bracket. During defrost, water drains from the base, and the factory base-pan heater helps keep that water from freezing inside the unit.
We set the outdoor unit where it has its required clearances, stays clear of snow drifts and can drain freely, using the right stand or bracket for the location.
Electrical, line-set and condensate requirements
The system runs on 208/230 V, single-phase, 60 Hz power. Lennox lists a minimum circuit ampacity of 21 A and maximum overcurrent protection of 30 A for the MWLD024S6S-1P. The outdoor unit powers the indoor unit through a 14 AWG three-conductor interconnect cable.
Refrigerant lines connect with flare fittings: ¼-inch liquid and ⅝-inch gas. Lennox allows up to 98 ft of piping and up to 66 ft of height difference between the indoor and outdoor units.
The indoor unit removes moisture while cooling and has a ¾-inch condensate drain connection. The drain line needs a continuous downward route to a suitable discharge point; where gravity drainage is not possible, Lennox offers condensate pumps as an accessory.
Standard installation covers the typical arrangement. If your home needs anything extra, such as a new electrical circuit or a longer line route, we go over it with you before you order.
Mini-split installation in Toronto and the GTA
Start with one call to HVAC Market and tell us about the space and the comfort problem. Our experts help you choose the equipment and explain the installation process. A room that needs summer cooling, a new addition and a space heated by baseboards can lead to different priorities.
If the home needs anything beyond standard installation, we go over it before you order. You are not left to translate the technical requirements into an installation plan alone.
We supply this system with standard installation included, using licensed and insured technicians. We include free GTA delivery. We also offer free removal and disposal of the old unit, with the replacement arrangement explained alongside the work.
After you order, one of our HVAC experts calls to go over the order and schedule installation. Online ordering uses the $100 deposit route, with the remaining balance after installation. A phone order can arrange delivery without a deposit.
Our technicians test the controls and show you how to run the new system. We register the manufacturer warranty free of charge and provide our one-year installation labour warranty.
Ideal applications
A 2-ton single-zone system like this suits a large open main floor, a big great room or a well-insulated open basement. It is a natural choice wherever ducts are missing or impractical: additions, converted garages, finished attics and basements, and older homes heated by baseboards or radiators.
It also works well as a second system. Homes with central air often have one area that never gets comfortable, such as a bonus room over the garage or a top-floor bedroom. A dedicated mini-split solves that area without changing the main system.
One indoor unit gives one zone of control. If several separate rooms each need their own temperature, a multi-zone system or more than one single-zone system is usually the better plan.
Compare neighbouring sizes, and ductless versus central
The first table compares this system with the MWLD sizes next to it, all from the same Lennox data. The second compares a single-zone ductless system with other ways to heat and cool.
Within the MWLD family, smaller sizes are usually the most efficient on paper, and larger sizes add output for bigger open areas. Choosing the size that matches the space keeps the inverter running in its efficient low-speed range for longer, which is better for comfort than buying extra capacity just in case.
| Lennox pair | Cooling / heating and efficiency | Planning range |
|---|---|---|
| Next size down: MWLD018S6S-1P / MWMD018S6-1P | 18,500 / 20,000 BTU/h; 21.0 SEER2 / 9.7 HSPF2 | 900–1,200 sq. ft. |
| This system: MWLD024S6S-1P / MWMD024S6-1P | 22,000 / 25,000 BTU/h; 20.0 SEER2 / 9.5 HSPF2 | 1,200–1,500 sq. ft. |
| Approach | How it distributes heat and cooling | Best suited to |
|---|---|---|
| This single-zone ductless system | One wall-mounted indoor unit, no ducts | One room or open area, additions, homes without ducts |
| Multi-zone ductless system | Several indoor units on one multi-zone outdoor unit | Several rooms that each need their own temperature |
| Central air or central heat pump | Furnace or air handler through a duct network | Whole homes with suitable ductwork |
| Electric baseboards | Resistance heat in each room, no cooling | Backup heat alongside a heat pump |
Lennox warranty and our installation labour warranty
Lennox's basic limited warranty for the MWLD outdoor unit covers the compressor for seven years, all other covered components for five years, and accessories and controls for one year. The MWMD indoor unit's covered components carry five years, with accessories and controls at one year.
Because we install it, you get the full Lennox manufacturer warranty, and we register it for you free of charge. You do not need to fill in any registration yourself.
On top of the equipment coverage, we provide our one-year installation labour warranty on our installation work. The Lennox Basic Limited Warranty on lennox.com has the full equipment terms.
Any other questions? Call us at (437) 223-9253. We're always happy to help.
Frequently asked questions
The MWMD024S6-1P wall-mounted indoor unit. Lennox lists MWLD024S6S-1P with MWMD024S6-1P as a matched, AHRI-rated single-zone system, and the wireless remote controller comes with the indoor unit.
Yes. It is a heat pump, rated at 22,000 BTU/h of cooling and 25,000 BTU/h of heating, with heating operation down to −22°F (−30°C).
About 24,400 BTU/h at 5°F (−15°C) and about 11,600 BTU/h at −22°F (−30°C), from Lennox's capacity table with the room at 70°F. On the coldest nights, a backup heat source is often kept for the space.
About 1,200–1,500 sq. ft. as a planning guide. Windows, insulation, ceiling height and layout move a space up or down that range, and we help you choose between neighbouring sizes.
The indoor unit is listed at 28 / 47 dBA (low / high fan), and the outdoor unit at 54 dBA in cooling at Lennox's test position.
Yes. The MWMD024S6-1P has built-in Wi-Fi for the SmartThings app, with remote control, schedules, voice assistants and energy-use estimates.
Yes. Standard installation and free GTA delivery are included, using licensed and insured technicians. If your home needs anything extra, we go over it before you order, and our technicians test the controls and show you how to run the system.
Seven years on the compressor and five years on other covered components from Lennox. With our installation you keep the full Lennox manufacturer warranty, we register it free of charge, and we add our one-year installation labour warranty.
Yes. Online orders use a $100 deposit, with the remaining balance after installation. Phone orders can arrange delivery without a deposit.
Furnaces
Garage Heaters
Air Conditioners
Air Handlers
Heat Pumps
Mini- Splits
Tank Water Heaters
Tankless Water Heaters
Combi-Boilers
Boilers
ERV (Energy Recovery Ventilators)
HRV (Heat Recovery Ventilators)
Humidifiers
Filter Cabinets
Air Purifiers